• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.18.2016.tde-28092016-154251
Document
Author
Full name
Ronan Cleber Contrera
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2003
Supervisor
Committee
Schalch, Valdir (President)
Hamada, Jorge
Rodrigues, José Alberto Domingues
Title in Portuguese
Tratamento biológico de líquidos percolados de aterros sanitários utilizando reator anaeróbio horizontal de leito fixo (RAHLF)
Keywords in Portuguese
Aterro sanitário
Líquidos percolados
Reator anaeróbio horizontal de leito fixo
Resíduos sólidos urbanos
Tratamento biológico
Abstract in Portuguese
Ainda são poucas as cidades brasileiras que dão destino adequado aos seus resíduos sólidos urbanos. A disposição de resíduos em aterros sanitários é hoje uma das formas mais econômicas e adequadas de disposição. A grande quantidade de matéria orgânica presente nos resíduos domiciliares, a umidade própria dos resíduos, a infiltração de águas de chuvas e as atividades microbiológicas, faz com que se gere no interior dos aterros os líquidos percolados. Esses líquidos apresentam elevada demanda química de oxigênio (DQO) e são potencialmente poluidores. Este trabalho avaliou a eficiência e a viabilidade da utilização de um reator anaeróbio horizontal de leito fixo (RAHLF), no tratamento de líquidos percolados coletados nos aterros sanitários de Bauru-SP e Rio Claro-SP. O reator, em escala piloto, constituiu-se de um tubo de PVC com 3,0 m de comprimento e 14,5 cm de diâmetro interno, perfazendo uma relação comprimento por diâmetro (L/D) de aproximadamente 20 e volume de aproximadamente 50 L. O reator possuía coletor de gases e amostradores intermediários ao longo do comprimento, em posições correspondentes a L/D de 4, 8, 12 e 16. Como suporte de imobilização foi utilizada espuma de poliuretano com densidade de 20 kg.m-3 na forma de cubos de aproximadamente 10 mm de lado. Os percolados foram coletados e armazenados em uma câmara fria a 5ºC e o reator foi mantido com temperatura controlada em uma câmara a 30ºC. Ao se operar o sistema por oito semanas, com o percolado coletado em Bauru-SP, não houve adaptação da biomassa devido, provavelmente, às altas concentrações de NH3. Utilizando o percolado de Rio Claro-SP, o sistema apresentou inicialmente baixas eficiências, mesmo com tempo de detenção hidráulica de 25 dias. Mas após mudanças na estratégia de operação, utilizando-se um substrato sintético na adaptação e a substituindo-se o percolado por outro coletado no mesmo aterro, o sistema reagiu muito bem, obtendo-se eficiências de aproximadamente 80% em termos de remoção de DQO, com tempo de detenção hidráulica de 2,5 dias e com DQO afluente da ordem de 5.000 mg/L.
Title in English
Biological treatment of sanitary landfill leachate using a horizontal anaerobic immobilized sludge reactor
Keywords in English
Biological treatment
Horizontal anaerobic immobilized sludge reactor
Leachate
Sanitary landfill
Urban solid wastes
Abstract in English
Even today, only few Brazilian cities give adequate destiny to urban solid wastes. The waste disposal at sanitary landfills is currently one of the most economical and adequated way of waste disposal. The high quantity of organic matter in domiciliary wastes, the waste own moisture, the rainwater infiltration and the microbiological activities lead to the leachate generation into the landfill. This liquid has a high chemical oxygen demand (COD) concentration, and is a potential pollutant. This work evaluated the viability and the efficiency of the use of a horizontal anaerobic immobilized sludge reactor (HAIS reactor) for leachate treatment collected from Bauru-SP and Rio Claro-SP landfills. The reactor, in pilot scale, was constructed using a 3,0 m of length and 14,5 cm internal diameter PVC pipe, with a length-diameter ratio (L/D) of approximately 20, and an approximately 50 L volume. The reactor had gas collectors and intermediate samplers in the direction of its length, in positions corresponding to L/D equal to 4, 8, 12 and 16. For immobilization support it was utilized polyurethane foam with 20 kg.m-3 of density in cube form, with side of approximately 10 mm. The leachate was collected and stored in a cold chamber at 5ºC and the reactor was maintained at controlled temperature in a chamber at 30ºC. Operating the system with the leachate from Bauru-SP during eight weeks, there was no biomass acclimatization due, probably, to high NH3 concentrations. When utilizing the leachate from Rio Claro-SP the system had, initially, low efficiencies, even with a hydraulic retention time of 25 days. But after changes in the operation strategy, changing the leachate by one other collected in the same place, the system reacted very well, obtaining efficiencies of approximately 80% in terms of COD removal, with a hydraulic retention time of 2,5 days and an inlet COD at the range of 5.000 mg/L.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2016-09-28
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.