• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.18.2015.tde-26052015-164155
Document
Author
Full name
Clara Vieira de Faria
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2015
Supervisor
Committee
Silva, Maria Bernadete Amâncio Varesche (President)
Gomes, Simone Damasceno
Ribeiro, Rogers
Title in Portuguese
Remoção e degradação de alquilbenzeno linear sulfonado de água residuária de lavanderia diluída em esgoto sanitário
Keywords in Portuguese
CG/EM
Granulometria
Reator anaeróbio
Surfactante aniônico
Abstract in Portuguese
A remoção do surfactante Alquilbenzeno Linear Sulfonado (LAS) de água residuária de lavanderia comercial foi estudada em EGSB (Expanded granular sludge bed). Essa água residuária foi diluída em esgoto sanitário. O volume útil do reator era de 1,8 L. Toda a operação ocorreu em condições mesofílicas, para TDH (tempo de detenção hidráulica) de 36 horas, velocidade ascensional de 4 m/h e vazão de recirculação de 8,5 L/h. A água residuária de lavanderia era diluída até que se atingisse aproximadamente 20 mg/L de LAS na alimentação do reator. O sistema foi operado em três fases. Na primeira fase de operação usou-se água de abastecimento para diluir a água residuária de lavanderia; na segunda fase utilizou-se uma mistura de água de abastecimento e esgoto sanitário para diluição da água residuária de lavanderia, sendo que 50 % da composição era esgoto sanitário; e, por fim, na última fase de operação utilizou-se apenas esgoto sanitário como diluente da água residuária. Na primeira fase foi necessária adição de bicarbonato de sódio como agente tamponante. Em todas as fases aplicou-se DQO (demanda química de oxigênio) e LAS afluente de 341 ± 216 mg/L e 18,8 ± 7,3 mg/L, respectivamente. A adição do esgoto sanitário afetou a remoção do surfactante, o que na fase inicial (Fase I) representou 77,2 ± 14,9 % e na fase final (Fase III) passou a ser 55,3 ± 18,4 % de remoção de LAS. No entanto, ao passo que a remoção de LAS diminuiu, a remoção de DQO aumentou de 57 ± 16 % para 65 ± 10 %, respectivamente, para a Fase I e Fase III. Além disso, devido a adição de esgoto sanitário verificou-se aumento do tamanho dos grânulos, de 3,67 ± 1,83 mm (Fase I) para 4,97 ± 1,99 mm (Fase II); e também da concentração de sólidos totais no reator, de 5,79 g/L (Etapa I) para 9,50 g/L (Fase III). Por meio do balanço de massa de LAS verificou-se remoção de 69 % de LAS, sendo que 67 % foram removidos por degradação e 2 % por adsorção do mesmo na biomassa. Por fim, por meio das análises por CG/EM (Cromatografia gasosa acoplada a espectrometria de massas) observou-se 17 substâncias no afluente e apenas 4 no efluente, tais como, mercaptanas, hidrocarbonetos, aminas e amidas. A maioria delas são tóxicas aos organismos aquáticos e estão presentes em produtos de limpeza e higiene pessoal.
Title in English
Removal and degradation of linear alkylbenzene sulfonate of laundry wastewater diluted in sewage
Keywords in English
Anaerobic reactor
Anionic surfactant
GC/MS
Grain size
Abstract in English
The removal of the surfactant Linear Alkylbenzene Sulfonate (LAS) of wastewater of a commercial laundry was studied in an EGSB (Expanded granular sludge bed). This wastewater was diluted in sewage. The useful volume of the reactor was of 1,8 L. The whole operation occurred on mesophilic conditions, to HRT (Hydraulic Retention Time) was 36 hours, the upflow speed of 4 m/h and recirculation flow of 8,5 L/h. The laundry waste water was diluted until achieve 20 mg/L of LAS on the reactor feed. The system was operated in three stages. In the first operation stage water supply was used to dilute the wastewater laundry; in the second stage used a mixture of water supply and sewage for dilution of wastewater laundry and 50 % of the composition was sewage; and finally, in the last stage of operation is only used sewage as a diluent of wastewater. In the first stage was required addition of sodium bicarbonate as buffering agent. All the stages was applied COD (Chemical oxygen demand) and LAS influent 341 ± 216 mg/L and 18,8 ± 7,3 mg/L, respectively. The addition of sewage affected the surfactant removal, which on the first stage (Stage I) represented 77,2 ± 14,9 % and on the final stage (Stage III) became 55,3 ± 18,4 % of LAS removal. However, while removing of LAS decreased the COD removal increased from 57 ± 16 % to 65 ± 10 %, respectively, to Stage I and Stage III . Furthermore, due to the addition of sewage was checked an increased on the size of the grain from 3,67 ± 1,83 mm (Stage I) to 4,97 ± 1,99 mm (Stage II); and also the concentration of total solids into the reactor, from 5,79 g/L (Stage I) to 9,50 g/L (Stage III). By mass balance LAS was found a remove of 69 % of LAS, wherein 67 % were removed by degradation and 2 % by adsorption of the surfactant in the biomass. Finally, through analysis by GC/MS (gas chromatograph/mass spectrometry) 17 substances were observed in the influent and only 4 in the effluent, such as, mercaptans, hydrocarbons, amines and amides. Most of them are toxic to aquatic organisms and are present in cleaning products and personal hygiene.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2015-06-12
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.