  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.18.2016.tde-24112016-151517
Documento
Autor
Nombre completo
Marcelo Romano Modolo
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2002
Director
Tribunal
Daniel, Luiz Antonio (Presidente)
Matsumoto, Tsunao
Zaiat, Marcelo
Título en portugués
Utilização de reatores enzimáticos como unidades de pré-tratamento para sistemas de lodos ativados utilizando esgoto sintético a base de lipídios
Palabras clave en portugués
Lipase
Lipídios
Lodos ativados
Reator enzimático
Resumen en portugués
Sabe-se que as águas residuárias, contendo elevadas concentrações de lipídios, causam problemas às unidades convencionais de tratamento podendo gerar lodo altamente biodegradável e sistemas com baixos rendimentos na remoção da matéria orgânica. Com o intuito de estudar a possibilidade de se obter eficiências maiores de remoção de matéria orgânica no tratamento de águas residuárias com elevados teores de lipídios, empregou-se na presente pesquisa processo alternativo de tratamento denominado de sistema combinado, composto de um reator enzimático (R1) e de um reator de lodos ativados (R2). Visando realizar a pré-hidrólise dos lipídios afluentes, o reator enzimático, contendo a enzima lipase LIPOLASE 100T, imobilizada em suporte de polietileno, foi instalado antecedendo o reator de lodos ativados. Paralelamente, foi construída outra unidade de lodos ativados (Rc) similar a primeira, porém sem o reator enzimático acoplado, denominada sistema de controle, visando possibilitar a comparação dos resultados obtidos. A unidade experimental foi operada durante 94 dias, em regime contínuo com a temperatura em torno de 30ºC. Os reatores de lodos ativados, R2 e Rc, foram operados, cada, com TDH de 8 horas e vazão de 3,4 L/dia. As eficiências médias de remoção de DQO bruta obtidas foram respectivamente de 85% e 79% para os sistemas combinado e de controle. A eficiência média de remoção de óleos e graxas do sistema combinado foi de 91%, enquanto que para o sistema de controle a eficiência média foi de 84%. Assim, os resultados obtidos no presente trabalho, demonstraram que as vantagens obtidas com o emprego do sistema combinado proposto, sob as condições específicas da presente pesquisa, foram significativas.
Título en inglés
Utilization of enzymatic reactors, as units of pre-treatment for activated sludge systems using synthetic wastewater based on lipids
Palabras clave en inglés
Activated sludge
Enzymatic reactor
Lipase
Lipids
Resumen en inglés
The wastewaters containing high concentrations of lipids, cause problems to the conventional units of treatment being able to produce highly biodegradable sludge and systems with low organic matter removal. In order to study the possibility of obtaining high efficiencies of organic matter removal in the treatment of wastewater with high contents of lipids, it was used in the present research an alternative procedure of treatment named combined system, composed of an enzymatic reactor (R1) and an activated sludge reactor (R2). In order to achieve the pre-hydrolysis of the affluent lipids, the enzymatic reactor, containing the lipase enzyme LIPOLASE 100T immobilized in polyethylene support, was installed preceding the activated sludge. Parallely, it was built another unit of activated sludge (Rc) similar to the first, but without the enzymatic reactor coupled, named control system, in order to enable the comparisons of the results obtained. The experimental unit was operated during 94 d, in continuous operation, with the temperature around 30°C. The activated sludge reactors, R2 and Rc, were operated, respectively, with hydraulic time residence of 8 h and flow rate of 3,4 L/d. The average efficiencies of removal raw COD obtained were respectively, of 85% and 79% for the combined and control systems. The average efficiency of removal of oil and greases of the combined system was of 91%, while for the control system the average efficiency was of 84%. So, the results obtained in this present work, showed that the advantages obtained with the use of the proposed system, under the specific conditions of the present research, were significant.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2016-11-24
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.