Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.18.2016.tde-21032016-150822
Documento
Autor
Nome completo
Sergio Brasil Abreu
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Carlos, 2003
Orientador
Banca examinadora
Zaiat, Marcelo (Presidente)
Nour, Edson Aparecido Abdul
Pires, Eduardo Cleto
Título em português
Estudo do desempenho de reator anaeróbio-aeróbio de escoamento ascendente no tratamento de esgoto sanitário com espuma de poliuretano como suporte de imobilização da biomassa
Palavras-chave em português
Biomassa imobilizada
Escoamento ascendente
Esgoto sanitário
Espuma de poliuretano
Reator de leito fixo
Tratamento anaeróbio-aeróbio
Resumo em português
O projeto consistiu na concepção e avaliação do desempenho de um sistema anaeróbio-aeróbio para tratamento de esgoto sanitário. O leito do reator foi dividido em quatro compartimentos de igual volume. Foi usada espuma de poliuretano para imobilização da biomassa e, para facilitar a partida do reator, esse material suporte foi previamente inoculado. O projeto teve três fases distintas: na primeira etapa, foi observada a importância da concentração de biomassa anaeróbia no desempenho de reator anaeróbio a princípio operado com metade do leito reacional com espuma e, a seguir, com o leito todo preenchido com espuma. Na segunda etapa, foram testados diferentes tempos de detenção hidráulica no reator que operou apenas em condições anaeróbias. Na última etapa foi operado o reator combinado anaeróbio-aeróbio. Ficou constatada a importância da concentração de microrganismos no desempenho do reator anaeróbio, pois com o aumento da quantidade de espuma, o reator atingiu resultados melhores e maior estabilidade operacional. Foi comprovada a influência do tempo de detenção hidráulica (TDH) no desempenho do reator. Tempos de detenção muito altos acarretam problemas de transferência de massa líquido-sólido, e baixos TDH dificultam adequada ação dos microrganismos. O melhor resultado para o reator em operação exclusivamente anaeróbia foi para o TDH de 10 horas, no qual se conseguiu reduzir a DQO de amostra bruta de 389 +/- 70 mg/L para 137 +/- 16 mg/L, em média. Para o reator operado anaeróbio-aeróbio a DQO de amostra bruta decresceu de 259 +/- 69 mg/L para 93 +/- 31 mg/L, em média. A comparação de todos os resultados obtidos, evidenciou a importância do pós-tratamento aeróbio na remoção de parcela de matéria orgânica não removida em tratamento unicamente anaeróbio.
Título em inglês
Study on the performance of an anaerobic-aerobic upflow reactor in the treatment of wastewater using polyurethane foam as a support for biomass immobilization
Palavras-chave em inglês
Anaerobic-aerobic treatment
Fixed bed reactor
Immobilized biomass
Polyurethane foam
Upflow
Wastewater
Resumo em inglês
The project consisted in the design and performance evaluation of an anaerobic-aerobic system for wastewater treatment. Polyurethane foam was used for biomass immobilization and, to smooth the reactor start-up, this supporting material was previously inoculated. The project was divided in three distinct phases. In the first one, the importance of the anaerobic biomass concentration was observed in the performance of the anaerobic reactor in a way to operate the reactor primarily with half of the reaction bed filled with foam and subsequently operate it with the bed completely filled with foam. In the second phase, different times of hydraulic retention were tested with the reactor operating exclusively in anerobic conditions. In the third and last phase, an anaerobic-aerobic combined reactor was operated. It was possible to confirm the importance of microorganism concentration in the performance of the anaerobic reactor, since the increase in the amount of foam allowed the reactor to reach better results and greater operational stability. The influence of the hydraulic retention time in the reactor performance was also proved. Very high retention times cause problems in the liquid-solid mass transference, while low retention times do not allow an adequate action of microorganisms. The best result for the reactor with an exclusive anaerobic operation was the 10 hour retention time, when it was possible to reduce the COD of a 389 +/- 70 mg/L gross sample to a 137 +/- 16 mg/L in average. On the other hand, for the anaerobic-aerobic operating reactor, the COD of a gross sample dropped from 259 +/- 69 mg/ L to 93 +/- 31 mg/L in average. Finally, comparing all the obtained results, it was possible to verify the importance of the anaerobic post treatment in the removal of a part of the organic matter not removed in an exclusively anaerobic treatment.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2016-03-22
 
AVISO: O material descrito abaixo refere-se a trabalhos decorrentes desta tese ou dissertação. O conteúdo desses trabalhos é de inteira responsabilidade do autor da tese ou dissertação.
  • ABREU, S B, e ZAIAT, M. Desempenho de Reator Anaeróbio-Aeróbio de Leito Fixo no Tratamento de Esgoto Sanitário [doi:10.1590/S1413-41522008000200008]. Engenharia Sanitária e Ambiental [online], 2008, vol. 13, p. 181-188.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.