Master's Dissertation
DOI
https://doi.org/10.11606/D.18.2008.tde-20022009-104355
Document
Author
Full name
Fausto de Assis Moraes
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2008
Supervisor
Committee
Reis, Luisa Fernanda Ribeiro (President)
Fernandes, Cristóvão Vicente Scapulatempo
Porto, Rodrigo de Melo
Title in Portuguese
Calibração de modelo de decaimento de cloro aplicado a setor de rede de distribuição de água
Keywords in Portuguese
Algoritmos genéticos
Cloro residual
Qualidade da água
Redes de distribuição de água
Vazamento
Abstract in Portuguese
O crescente adensamento populacional em grandes centros urbanos vem propiciando crescentes demandas hídricas. Esse fato aliado às limitações das fontes para abastecimento, tanto do ponto de vista quantitativo como qualitativo, impõe que políticas de gerenciamento da água sofram transformações no futuro próximo. Nesse sentido, devem merecer atenção especial as técnicas de reuso, bem como o uso racional e otimizado da água em meio urbano. O presente trabalho enfoca um dos principais aspectos do gerenciamento da qualidade da água para abastecimento, que é a manutenção do residual de cloro no interior da rede conforme a Portaria 518/2004. Trata-se de um problema complexo, uma vez que o cloro decai, ao longo do tempo, e se mistura nos nós da rede, sofrendo mudanças de concentração. Visando à modelagem e simulação do comportamento do cloro residual como uma ferramenta eficiente de gerenciamento dos sistemas de distribuição de água, muitos estudos têm sido realizados e reportados pela literatura assumindo-se que os efeitos do decaimento são representados pelos coeficientes Kbulk e Kwall. O presente trabalho realiza a calibração hidráulica e de qualidade para um setor de distribuição de água real do município de São Carlos - SP - Brasil, considerando o vazamento. Para tanto, calibradores hidráulicos já testados por outros autores foram usados, e um calibrador de qualidade para resolução do problema inverso, que utilizam em conjunto o simulador EPANET 2.0 e os algoritmos genéticos (AGs) como ferramenta de otimização, foram desenvolvidos. Foi evidenciada a importância de se considerar o vazamento na calibração hidráulica e conseqüentemente na calibração de qualidade. Foi desenvolvida também uma metodologia para a calibração dos parâmetros dos AGs através do uso do "Particle Swarm Optimization" (PSO). Foram testados ainda diversos modelos de vazamento para determinação de qual modelo seria capaz de representar de maneira mais fidedigna o comportamento hidráulico da rede e os resultados obtidos apontaram os modelos que admitem vazamento por comprimento linear da tubulação como sendo mais adequados.
Title in English
Calibration of the chlorine decay model applied to a prototype water supply distribution network sector
Keywords in English
Genetic algorithms
Leakages
Residual chlorine
Water distribution networks
Water quality
Abstract in English
The rising population density of large urban centers is gradually increasing water supply demands. This together with the paucity of water sources requires that the future water administration policies go through a transformation from both quantitative and qualitative points of view. Thus rational use of available water and water reuse deserve special attention in the urban environment. This study focuses on one these main aspects of water quality management, namely, the maintenance of residual chlorine in the hydraulic network according the respective Directive nº 518/2004. This is a complex problem in view of the fact chlorine decays in time and undergoes mixing at the network nodes, consequently producing changes in its concentration. Numerous studies on modeling and simulation of behavior of residual chlorine, as an efficient water distribution system management tool, have been made and reported in literature. These studies assume that chlorine decay in the network can be represented through Kbulk and Kwall coefficients. This research work conducts hydraulic and water quality calibration of a prototype water distribution sector in the city of São Carlos - SP - Brazil, while taking into account leakages in the network. Hydraulic calibration programs previously tested by others and a water quality calibration program were employed for the solution of the inverse problem for determination of unknown parameters. This problem was solved using hydraulic simulator EPANET 2.0 in conjunction with the genetic algorithms (AGs). These procedures showed the importance of considering network leakages in hydraulic calibration and consequently in the calibration of water quality. A method for the calibration of AG parameters was also developed through the use of "Particle Swarm Optimization" (PSO). Various representations for leakage were tested in order to identify the model that best described the hydraulic performance of the network. Thus it was possible to show that the models, which consider leakage per unit length, were the most adequate.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
FaustoMoraes.pdf (3.64 Mbytes)
Publishing Date
2009-05-04
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.