Disertación de Maestría
DOI
https://doi.org/10.11606/D.18.2014.tde-19012015-100324
Documento
Autor
Nombre completo
Paulo Marcos Faria Maciel
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2014
Director
Tribunal
Sabogal Paz, Lyda Patrícia (Presidente)
Franco, Regina Maura Bueno
Moruzzi, Rodrigo Braga
Título en portugués
Remoção de Giardia spp. e Cryptosporidium spp. em águas de abastecimento com turbidez elevada utilizando cloreto de polialumínio: estudo em escala de bancada e desafios analíticos
Palabras clave en portugués
C. parvum
Cryptosporidium spp.
Giardia spp.
Cloreto de polialumínio – PAC
Jarteste
Separação imunomagnética – IMS
Tratamento de água
Resumen en portugués
O objetivo deste trabalho foi avaliar o desempenho da remoção de cistos deGiardia spp. e oocistos de Cryptosporidium parvum, em águas de abastecimento com turbidez elevada, em experimentos em escala de bancada (coagulação, floculação, decantação e filtração). Para tanto, empregou-se o coagulante cloreto de polialumínio – PAC. O método de filtração em membranas foi adotado para a concentração de protozoários, seguido ou não da etapa de purificação por separação imunomagnética – IMS. Os métodos foram avaliados em experimentos de controle de qualidade analítica e o método sem IMS apresentou as seguintes porcentagens de recuperação, 80% ±16,32% para cistos de Giardia spp. e 5% ±10,00% para oocistos de C. parvum. O método com IMS apresentou 31,5%±7,55% de recuperação para cistos de Giardia spp. e 5,75%±3,20% de recuperação para oocistos de C. parvum. Os experimentos demonstraram que não houve melhora na remoção de ambos os protozoários na condição de maior dosagem de coagulante (65 mg.L-1 de PAC e pH 7,29). A condição de menor dosagem de coagulante (25 mg.L-1 de PAC e pH 6,76) apresentou um desempenho melhor, ao contrário de uma expectativa de que a maior dosagem de coagulante pudesse favorecer a remoção destes microrganismos. A condição de menor dosagem apresentou, na água filtrada, 50 e 75% de ausência de identificação de cistos de Giardia e oocistos de C. parvum, respectivamente. A condição de maior dosagem apresentou (oo)cistos na água filtrada de todas amostras analisadas. Estes resultados indicam a importância do controle da coagulação na remoção de protozoários.
Título en inglés
Giardia spp. Cysts and Cryptosporidium spp. Oocysts removal in high turbid drinking water using polyaluminum chloride: a bench scale study and analytical challenges
Palabras clave en inglés
C. parvum
Cryptosporidium spp.
Giardia spp.
Bench scale
Drinking water treatment
Immunomagnetic separation – IMS
Polyaluminum chloride – PACl
Resumen en inglés
The aim of this study was to evaluate the performance of Giardia spp. cysts and Cryptosporidium parvum oocysts removal in a bench scale experiment. The coagulant polyaluminium chloride – PACl was used in this research. The protozoa concentration tests were performed by applying the Membrane Filtration method, with and without Immunomagnetic Separation assay-IMS. The methods were evaluated using control experiments and the method without IMS had the following percentage recovery, 80% ± 16.32% and 5% ±10.00% for Giardia cysts and C. parvum oocysts, respectively. The method with IMS presented 31.5% ± 7.55% and 5.75% ± 3.20% of percentage recovery for Giardia cysts and C. parvum oocysts, respectively. Bench scale experimental results have clearly shown that there was no improvement in protozoa removal using the superior dosage of coagulant. The inferior dosage condition (25 mg.L-1 of PACl and pH 6,76) performed better, which was contrary to what was expected in which a superior dosage of coagulant could favour when removing microorganisms. The inferior dosage condition presented 50% and 75% of absence of Giardia cysts and C. parvum oocysts in the final water, respectively. The second coagulation condition (65 mg.L-1 of PACl and pH 7,29) presented protozoa (oo)cysts in the final water of all the samples examined. These results indicate the importance of coagulation control in protozoa removal.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2015-01-28
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.