• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.18.2012.tde-17102012-103326
Document
Author
Full name
Irene Monteiro da Franca Souza
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2012
Supervisor
Committee
Reali, Marco Antonio Penalva (President)
Cordeiro, João Sérgio
Daniel, Luiz Antonio
Title in Portuguese
Influência do gradiente médio de velocidade na zona de contato na eficiência de clarificação de água para abastecimento por flotação
Keywords in Portuguese
Flotação por ar dissolvido (FAD)
Gradiente médio de velocidade (G)
Telas
Tratamento de água para abastecimento
Zona de contato e zona de separação
Abstract in Portuguese
O presente trabalho teve como objetivo estudar a influência do gradiente médio de velocidade (Gzc), associado ao tempo de detenção hidráulico (tzc) e à taxa de aplicação superficial (TASzc), na zona de contato, na eficiência de clarificação de uma unidade retangular de flotação por ar dissolvido, em escala piloto, tratando água para abastecimento. Foram estudadas duas configurações da Unidade Piloto de Flotação por Ar Dissolvido (UPFAD) (A e B), as quais diferem no comprimento da zona de contato A (90 mm) e B (140 mm). A TASzc - A (133 ± 3 m/h) e B (86 ± 1 m/h) - e o tzc - A (54 ± 1s) e B (84 ± 1 s) - são diferentes. Foram avaliados três valores do Gzc A (1,8; 6,5;10,2) e B (0,9; 4,7; 6,3), através da inserção de telas com características diferentes no interior da zona de contato. E, Para cada valor de Gzc, foram investigados três valores de A/V (3,73; 4,90; 6,41). Em todos os ensaios realizados, foram fixados os seguintes parâmetros: vazão da água bruta preparada (5,4 m³/h); temperatura da água bruta preparada (26 ± 1ºC); pH de coagulação (6,5 ± 0,1); tempo de floculação (17,2 min); gradiente médio de velocidade de floculação (110 s-1); vazão de descarte após a floculação (0,8 m³/h); vazão de entrada para a flotação (Qe) (4,6 m³/h); velocidade de entrada para a flotação (ve) (180 m/h); velocidade cross-flow (45 m/h); TASzs (14,6 ± 0,2 m/h); pressão de saturação (4,5 ± 0,1 Kgf/cm²). A unidade piloto FAD foi alimentada com água preparada, que apresentou turbidez em torno de 7,4 ± 0,6 UNT, e cor aparente, em torno de 39,4 ± 4,3 UH. A fração removida dos parâmetros analisados para cada Gzc é menos sensível a variações de A/V na configuração A que na configuração B. Na configuração A, a tela que apresentou Gzc em torno de 6,5 s-1 gerou melhores resultados para cada A/V analisado. Na configuração B, a tela que gerou Gzc em torno de 4,7 s-1 proporcionou melhor fração removida de turbidez e cor para cada A/V estudado. Além disso, na configuração B, a fração removida de turbidez e cor foi menos sensível a variações de A/V, para Gzc de 4,7 s-1 que para os demais valores de Gzc. A tela que gerou resultados mais eficientes na configuração A foi a mesma para a configuração B. Portanto o uso da referida tela favoreceu o desempenho das configurações A e B. Comparando todas as situações estudadas nas duas configurações, o ensaio com a configuração A (com tzc de 54 s) com Gzc de 6,3 s-1 e A/V de 4,9 g/m³, apresentou as maiores frações de remoção de cor e turbidez.
Title in English
Influence of the velocity gradient in the contact zone in the efficiency of clarification of potable water by flotation
Keywords in English
Contact zone and separation zone
Dissolved air flotation (DAF)
Grilles
Treatment of potable water
Velocity gradient (G)
Abstract in English
The present work aimed to study the influence of velocity gradient (Gzc) associated with the hydraulic detention time (tzc) and the rate of surface application (TASzc) in the contact zone in the efficiency of clarification of a unit rectangular dissolved air flotation pilot scale, treating water supplies. Two different kinds of configurations of the reactor dissolved air flotation in pilot scale (UPFA) (A and B) were studied, which differ in the length of the contact zone - A (90 mm) and B (140 mm). The TASzc - A (133 ± 3 m/h) and B (86 ± 1 m/h) - and tzc - A (54 ± 1 s) and B (84 ± 1 s) were different. Three different values of Gzc were analysed - A (1.8, 6.5, 10.2 s-1) and B (0.9, 4.7, 6.3 s-1) by insertion of grilles with different characteristics within the zone contact. And for each value of Gzc, three values of A/V (3.73, 4.90, 6.41 g/m³) were investigated. In all trials, the following parameters were set: flow of synthetic raw water (5.4 m³/h), synthetic raw water temperature (26 ± 1ºC), coagulation pH (6.5 ± 0.1); flocculation time (17.2 minutes), the speed gradient flocculation (110 s-1); flow disposal after flocculation (0.8 m³/h), input flow to the flotation (Qe) (4, 6 m³/h), input speed for flotation (ve) (180 m/h), cross-flow velocity (45 m/h), TASzs (14.6 ± 0.2 m/h), saturation pressure (4.5 ± 0.1 kgf/cm ²). The pilot plant was fed with synthetic water, which showed turbidity of approximately 7.4 ± 0.6 NTU, and apparent color, about 39.4 ± 4.3 HU. The removal efficiency of the analyzed parameters for each Gzc is less sensitive to variations in the A/V in the configuration A than in the configuration B. In configuration A, the grille that showed Gzc about 6.5 s-1 gave better results for each A/V analysis. In configuration B, the grille that has generated Gzc around 4.7 s-1 provided the best removal efficiency of turbidity and color for each A/V studied. Furthermore, in the configuration B, the removal efficiency of color and turbidity was less sensitive to variations in A/V for Gzc 4.7 s-1 than for other values of Gzc. The grille that generated the best results in the configuration A was the same for the configuration B. Therefore the use of that grille favored the performance of configurations A and B. Comparing all the situations studied in two configurations, the test with the configuration A (with tzc the 54 s) with Gzc of 6.3 s-1 and A/V of 4.9 g/m³, had the highest removal efficiencies of color and turbidity.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2012-10-18
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.