Doctoral Thesis
DOI
https://doi.org/10.11606/T.18.2016.tde-16052016-104721
Document
Author
Full name
Cláudio Antônio de Andrade Lima
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2001
Supervisor
Committee
Foresti, Eugênio (President)
Belli Filho, Paulo
Campos, José Roberto
Melo, Henio Normando de Souza
Zaiat, Marcelo
Title in Portuguese
Tratamento de esgoto sanitário em reator anaeróbio horizontal de leito fixo (RAHLF): escala piloto
Keywords in Portuguese
Biomassa imobilizada
Esgoto sanitário
Hidrodinâmica
Reator de leito fixo
Tratamento anaeróbio de águas residuárias
Abstract in Portuguese
Este trabalho apresenta as avaliações de desempenho, das demandas operacionais e dos fatores intervenientes no aumento da escala da unidade piloto do Reator anaeróbio Horizontal de Leito Fixo (RAHLF) no tratamento de esgoto sanitário após passagem por peneira com malha de 1 mm, durante dois anos de operação. O reator dispunha de volume total de 237,5 1, construídos com tubos comerciais de PVC de 14,5 cm de diâmetro (D), dispostos em cinco módulos horizontais em série de 2,88 m, perfazendo um comprimento total de (L) de 14,4 m e relação de total de L/D de 100. O suporte de imobilização de biomassa, espuma de poliuretano em matrizes cúbicas de 1 cm de aresta, mostrou-se adequado ao desenvolvimento do biofilme. Em partida, sem inoculação prévia, ocorreu a sua consolidação a partir de 70 dias, com predominância de morfologia semelhante a Methanosaeta sp. em relação a da Methanosarcina. Em torno de 90 dias com afluente de 350 mg/l de DQO, observe-se a melhor qualidade do efluente, com valor de 100 mg/l de DQO. Em longa operação ocorreu queda de rendimento e menor reprodutibilidade das previsões do projeto, atribuída aos constantes entupimentos e ineficácia das operações de limpeza, com o comprometimento de volume reacional verificados por estudos de hidrodinâmica. Da investigação das origens dos equipamentos observou-se tratar mais de um efeito local e qualitativamente relacionado à biomassa retida que propriamente quantitativo e extensivo ao longo de todo reator, com produção continuada de polímeros extracelulares, promovendo um efeito sinérgico com os predominantes organismos filamentosos e com os sólidos particulados retidos no leito. Diante das potencialidades desta configuração de reator apontam-se alternativas de mitigação dos entupimentos e o direcionamento dos estudos necessários para novo aumento de escala para o tratamento de esgoto sanitário.
Title in English
Treatment of domestic sewage in a horizontal-flow anaerobic immobilized biomass (HAIB) reactor: pilot scale
Keywords in English
Anaerobic treatment of wastewaters
Fixed-bed reactor
Hydrodynamic
Immobilized biomass
Sewage
Abstract in English
This work evaluated the performance, the operational demands and the intervenient factors in the scale-up of the horizontal flow anaerobic immobilized biomass (HAIB) reactor pilot unit, treating domestic sewage previously screened. The operation was monitored for two years. The five- module (2.88 m length each) reactor volume was 237.5 liters and it was built with commercial PVC pipes of 14.5 cm of diameter (D), resulting in a total length (L) of 14.4 m and in a total ratio L/D of approximately 100. The immobilization support, cubic matrices of polyurethane foam (1 cm edge), showed to be suitable for the anaerobic biofilm development. During the start-up, without previous inoculation, the biofilm seemed to be consolidated after 70 days, and Methanosaeta sp. morphology predominated, in detriment of Methanosarcina. With an affluent of 350 mg COD/L, the best reactor performance was observed in about 90 days of operation (100 mg COD/L in the effluent). However, with the continuous operation, its performance decreased and the project predictions did not seem to fit anymore. These facts were probably due to the frequent cloggings ant the inefficiency of the backwashing procedures, leading to a decreasing of the operational volume. The origin of the clogging seemed to be related to the extracellular polymer production, linked to a synergic effect with the filamentous organisms and the particulate solids in the bed. Despite these operational problems, there were found alternatives to mitigate the clogging, and studies about a new scale-up methodology, in order to treat domestic sewage, were strongly recommended.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2016-05-16
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.