• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.18.2016.tde-16022016-131515
Documento
Autor
Nombre completo
Isabel Kimiko Sakamoto
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2001
Director
Tribunal
Vazoller, Rosana Filomena (Presidente)
Além Sobrinho, Pedro
Calijuri, Maria do Carmo
Manfio, Gilson Paulo
Pellizari, Vivian Helena
Título en portugués
Comparação da estrutura de comunidades microbianas presentes em sistemas de lodos ativados modificados para remoção biológica do fósforo em excesso, utilizando a técnica de eletroforese em gel de gradiente desnaturante (DGGE)
Palabras clave en portugués
Estrutura microbiana
PCR-DGGE
Processo de EBPR
Remoção biológica de fósforo
Sistemas de lodos ativados
Resumen en portugués
O excesso de nutrientes como nitrogênio e fósforo em efluentes de estação de tratamento de esgoto sanitário pode provocar a eutrofização nos corpos d'aguas receptoras. Esse processo gera efeitos negativos para a engenharia sanitária, dependendo do grau de qualidade e do uso de água requeridos. Para o abastecimento público, são exigidos métodos e processos de tratamentos avançados, quando a fonte hídrica está eutrofizada. Neste sentido, sistemas aeróbios de lodos ativados passaram a se destacar também como removedores de nutrientes por processos biológicos, após sofrerem algumas modificações operacionais. Um meio para otimizar o processo de remoção biológica do fósforo em excesso (EBPR) é promover condições ideais para o crescimento dos organismos acumuladores de fósforo. Esse trabalho teve como objetivo avaliar uma estação piloto de lodos ativados modificados, para a remoção de fósforo em excesso, utilizados no tratamento de esgoto sanitário, localizada na ETE da cidade de Tóquio - Japão. Essa estação piloto constituía-se de três sistemas de reação (1, 2 e 3), sendo que cada sistema era compartimentado e submetido às condições anaeróbia, anóxica e aeróbia. A avaliação dos três sistemas de reação, consistiu na verificação do desempenho deles com relação a DBO e fósforo e monitoramento da estrutura da comunidade microbiana, pela técnica da eletroforese em gel de gradiente desnaturante (DGGE). O desempenho em relação a DBOs (mg/L) nos três sistemas de reação, sempre foi superior a 90% e a eficiência da remoção do fósforo (%) na forma de fosfato (P-PO4 - mg/L) foi superior, em geral, a 70%, considerando os valores de entrada das alimentações e saída no último compartimento dos três sistemas de reação. Verificou-se que a estrutura da comunidade microbiana apresentou uma grande diversidade, devido aos números de bandas padrões encontradas nas amostras analisadas. Observou-se também uma grande similaridade ) da estrutura da comunidade microbiana nos sistemas estudados, possivelmente, relacionada ao mesmo afluente (esgoto sanitário) e ao mesmo tipo de recirculação interna e do lodo. As mudanças das estruturas das comunidades microbianas foram pequenas, diante das mudanças temporais e operacionais. No entanto, observou-se que o sistema foi menos eficiente (parâmetros de desempenho), frente a essas mudanças, o que pode estar mais relacionado à redução das atividades dos microrganismos do que com as estruturas microbianas.
Título en inglés
Comparison of the microbial communities structure in systems of activated sludge modified for enhanced biological phosphorus removal by denaturing gradient gel electrophoresis technique (DGGE)
Palabras clave en inglés
Activated sludge systems
Biological phosphorus removal
EBPR process
Microbial structure
PCR-DGGE
Resumen en inglés
The excess of nutrients such as nitrogen and phosphate in effluents of treatment plants for sanitary sewage can cause eutrophication in the receiving body of water. Given that process generates negative effects for the sanitary engineering depending on the degree of the quality and of the requested use of water. For the public provisioning, methods and processes of advanced treatments are demanded, when the water body is eutrophic. In this sense, aerobic systems of activated sludge have been expanded also to the processes of biological removal of nutrients after some operational modifications. By means of the optimization process of enhanced biological phosphorus removal (EBPR) will promote ideal conditions for the growth of polyphosphate accumulating organisms. This work had as its objective to evaluate a pilot station modified activated sludge, used for the treatment of sanitary sewage, but specifically for the enhanced phosphorus removal, located in the ETE of the city of Tokyo - Japan. These pilot station was constituted of three reaction systems (1, 2 and 3), and each system were composed of compartments and were submitted to anaerobic, anoxic and aerobic conditions. The evaluation of the three reaction systems, consisted of the verification of the performance of the systems with regard to BOD and phosphate which were monitored through microbial community's structure, for the biological phosphorus removal technique (DGGE). The performance in relation to the BODS (mg/L) in the three reaction systems was always above 90% and the efficiency of the removal of phosphorus (%) in the form of phosphate (P-PO4 - mg/L) was in general better than 70%, considering the values of influent and effluent from the last compartment of the three reaction systems. It was verified that the microbial community structure presented a great diversity, due to the standard numbers of bands found in the analyzed samples. A great similarity of the microbial community structure was observed in the studied systems, possibly being related to the same influent (domestic sewage) and to the same type of intern recirculation and of the sludge. The changes of the microbial communities structures were small, before the temporary and operational changes. However, it was observed that the system was less effiecient (performance parametrs) front to those changes, what can be more related the reduction of the activities of the microorganisms than with the microbial structures.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2016-02-17
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.