• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.18.2015.tde-13082015-144101
Documento
Autor
Nombre completo
Vinícius Mori Válio
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2015
Director
Tribunal
Marra Júnior, Wiclef Dymurgo (Presidente)
Dornelles, Kelen de Almeida
Giorgetti, Marcius Fantozzi
Título en portugués
Análise do material particulado atmosférico em uma região de São Carlos-SP
Palabras clave en portugués
Material particulado
Precipitação
Qualidade do ar
Resumen en portugués
O presente trabalho avaliou a qualidade do ar de uma área central da cidade de São Carlos-SP, mais precisamente no campus 1 da Universidade de São Paulo. Nessa região há grande movimentação de pessoas e veículos, principalmente durante o horário comercial. Esta avaliação foi feita com base na determinação de um dos parâmetros utilizados para verificar a qualidade do ar, o material particulado (MP) inalável em suspensão, ou seja, partículas que possuem diâmetro aerodinâmico menor ou igual a 10 μm e podem penetrar no sistema respiratório, sendo portanto, nocivas à saúde humana. O MP foi determinado em suas frações de 2,5 e 10 μm de diâmetro (MP10 e MP2,5). Duas metodologias diferentes foram utilizadas para determinar a concentração do material particulado em suspensão, fotometria por espalhamento de luz, através do equipamento ADR-1500 e gravimetria, através do PEM (Personal Enviromental Monitor). Os valores obtidos pelo método gravimétrico foram superiores aos resultados encontrados através da fotometria. As concentrações obtidas foram comparadas com os limites recomendados pela Organização Mundial da Saúde para o MP em suas frações de 2,5 e 10 μm, iguais respectivamente a 25 e 50 μg/m3. Além do material particulado foram obtidos dados para temperatura, umidade relativa e precipitação. As médias obtidas para as concentrações de MP10 e MP2,5, com o método gravimétrico, o qual fornece os resultados mais confiáveis, foram iguais respectivamente a 48,8 e 23,1 μg/m3, muito próximas portanto, de seus limites correspondentes. As menores concentrações obtidas para o MP10 foram, em sua maioria, verificadas em dias chuvosos, tanto através do PEM como do ADR. As concentrações de MP2,5, obtidas somente através do PEM, também apresentaram os menores valores em dias com chuva. Foi desenvolvido um modelo matemático que prevê o comportamento do MP10 durante as precipitações, evento este que se mostrou o mais importante na influência da concentração de material particulado atmosférico.
Título en inglés
Analysis of atmospheric particulate matter in a region of São Carlos-SP
Palabras clave en inglés
Air quality
Particulate matter
Precipitation
Resumen en inglés
This study evaluated the air quality of a central area of the city São Carlos-SP, more precisely on the Campus 1 of the University of São Paulo. In this region there is a large movement of people and vehicles, manly during business hours. This evaluation was made based on determination of one parameter used to verify air quality, the inhalable particulate material (PM) suspended in the air, in other words, particles which have aerodynamic diameter less or equal to 10 μm and can penetrate in the respiratory system, therefore, harmful to human health. The PM was determined in its fractions from 2,5 and 10 μm of diameter (PM10 e PM2,5).). Two different methodologies were used to determinate the concentration of particulate suspended material, photometry by scattered light, using the equipment ADR-1500, and gravimetry, thru PEM (Personal Environmental Monitor). The data obtained from gravimetry were higher than the results found thru photometry. The concentrations found were compared to the limits recommended by World Health Organization for PM and its fractions of 2,5 and 10 μm, equal to 25 and 50 μg/m3. Besides PM, temperature, relative humidity and precipitation were measured. The average values for the concentrations of PM10 and PM2,5 , using gravimetry, which provide more reliable results, it were equal to 48,8 and 23,1 μg/m3, therefore really close to their corresponding limits. The lower concentrations seen for PM10 were, mostly, verified on rainy days, using PEM and ADR. The concentrations of PM2,5 , obtained just using PEM, also had the lowest values during rainy days. A mathematical model was developed to predict PM10 behavior during precipitations, this event has shown to have the most important influence on the concentration of atmospheric particulate matter.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2015-08-18
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.