Master's Dissertation
DOI
https://doi.org/10.11606/D.18.2016.tde-12092016-105327
Document
Author
Full name
Luci Sartori
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 1998
Supervisor
Committee
Reali, Marco Antonio Penalva (President)
Campos, José Roberto
Mendes, Carlos Gomes da Nave
Title in Portuguese
Influência do uso de polímeros sintéticos no desempenho da flotação por ar dissolvido aplicada no tratamento de água para abastecimento
Keywords in Portuguese
Floculação com polímeros
Flotação com polímeros
Flotação por ar dissolvido
Tratamento de água
Abstract in Portuguese
O uso de polímeros sintéticos como auxiliares de floculação no tratamento de águas para abastecimento é uma prática que vem sendo bastante estimulada. Contudo o uso na floculação visando a flotação de águas para abastecimento tem sido pouco estudado. Neste trabalho, são apresentados os resultados de estudo da influência da aplicação de polímeros sintéticos como auxiliares de floculação na clarificação, por flotação, de água preparada com cor elevada (100 ± 9,0 uC) e baixa turbidez (6,80 ± 1,0 uT). Foram investigados três diferentes tipos de polímeros (catiônico, aniônico e não iônico), aplicados conjuntamente ao coagulante primário (sulfato de alumínio). Após a otimização da dosagem deste coagulante (40 mg/L), sem emprego de polímeros, foi estudado o desempenho da flotação diante a redução da dosagem de coagulante conjugado à aplicação de diferentes dosagens de polímeros. Também foram investigadas a influência do tempo decorrido após a mistura rápida para a adição do polímero, e do tempo e gradiente médio de velocidade na floculação para a flotação. Foram utilizadas duas unidades de flotação por ar dissolvido, uma em escala de laboratório (Flotateste) e outra em escala piloto (com escoamento contínuo). Após a adequação dos parâmetros de floculação, os ensaios obtidos com o flotateste mostraram que a aplicação de 0,25 mg/L de polímero não iônico permitiu a redução de 50% na dosagem de coagulante, sem queda significativa na eficiência de remoção de cor e turbidez (96% e 93% respectivamente). Por sua vez, o polímero catiônico, na dosagem de 0,25 mg/L, possibilitou redução de 70% na dosagem de sulfato de alumínio, com eficiência de remoção de cor e turbidez de 90%. A instalação piloto de flotação operando com TASap de 262 m3/m2d, e aplicação de polímeros, nas condições otimizadas com o flotateste, foi capaz de fornecer bons resultados de remoção de cor aparente (82% e cor no efluente de 18,6 uC) e de turbidez (80% com turbidez de 1,40 uT no efluente). Nos ensaios com a unidade piloto de flotação operando com TASap de 525 m3/m2d, com redução de 70% na dosagem de coagulante (aplicação de 0,25 mg/L de polímero catiônico), observou-se redução de até 79% na massa de Iodo gerada.
Title in English
Influence of synthetic polymer usage on the performance of dissolved air flotation applied to supply water
Keywords in English
Dissolved air flotation
Flocculation with polymers
Flotation with polymers
Supply water treatment
Abstract in English
The usage of synthetic polymers as flocculation aids for the treatment of supply water is a practice which have been widely stimulated, however its usage in flocculation aiming supply water flocculation has been scarcely studied. This work presents the results of the study of the influence of synthetic polymer application as a flocculation aids for clarifying prepared water containing high levei of color (100 ± 9.0 CU) and low turbidity (6.80 ± 1.0 NTU) through flotation. Three different kinds of polymers were investigated - cationic, anionic and non-ionic - which were applied together with the primary cogulant (aluminium sulphate). After the optimization of this coagulant dosage (40 mg/L), without the utilization of polymers, it was studied the flotation performance by the reduction of the coagulant dosage together with the application of different polymer dosages. It was also studied the influence of the time after rapid mixing for the polymer addition, and of time and average velocity gradient and flotation. Two units of dissolved air flotation were used, a bench unit and a pilot plant unit (with continuous flow). After the flocculation parameters adequacy, the essays obtained with FLOTATESTE showed that the application of 0.5 mg/L of non-ionic polymer allowed a reduction of 50% on coagulant dosage, without meningful drops of the color and turbidity removal efficient (96% and 93% respectively). On the other hand, the cationic polymer, at 0.25 mg/L, enabled a 70% reduction on the aluminium sulphate dosage with color and turbidity removal efficiency of 90%. The plant flotation unit, operating under a flow rate of 262 m3/m2d and with polymer application, under conditions optimized by FLOTATESTE, was able to provide good results of colour removal (82% and effluent color of 18.6 CU) and turbicity removal (83% with turbicity of 1.23 NTU in the effluent). In the essays with the pilot plant flotation unit, operating under a flow rate of 525 m3/m2d after reduction of 70% on the coagulant dosage (application of 0,25 mg/L of cationic polymer) , an up to 79% reduction in mass of sludge generated was observed.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2016-09-12
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.