• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.18.2016.tde-10052016-155934
Document
Author
Full name
Guilherme Lelis Giglio
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2015
Supervisor
Committee
Paz, Lyda Patrícia Sabogal (President)
Franco, Regina Maura Bueno
Guimarães, José Roberto
Title in Portuguese
Avaliação de diversos métodos de detecção de cistos de Giardia spp. e Oocistos de Cryptosporidium parvum presentes no resíduo gerado após o tratamento de água de abastecimento com turbidez elevada
Keywords in Portuguese
Cryptosporidium parvum
Giardia spp.
cloreto de polialumínio – PAC
jarteste
protozoário
resíduo de tratamento de água
separação imunomagnética – IMS
Abstract in Portuguese
Este trabalho teve como objetivo avaliar diversos métodos de detecção e recuperação de cistos de Giardia spp. e de oocistos de Cryptosporidium parvum em resíduos gerados no tratamento de águas de abastecimento com turbidez elevada tendo como padrão o Método 1623.1 da USEPA (2012 ). Para tanto, ensaios utilizando aparelho Jarteste (coagulação, floculação, decantação e filtração ) foram realizados utilizando o coagulante cloreto de polialumínio - PAC. Em todos os métodos avaliados foi utilizada a técnica de purificação por separação imunomagnética - IMS. A adaptação do método floculação em carbonato de cálcio FCCa elaborado por Vesey et al. (1993) e adaptado por Feng et al. (2011), repercutiu nos melhores resultados para a amostra de resíduo sedimentado, com recuperações de 68 ± 17 % para oocisto de C. parvum e de 42 ± 7 % para cisto de Giardia spp. Entretanto, as recuperações para a amostra de água de lavagem dos filtros - ALF foram inferiores à 1 %, não sendo possível determinar um método adequado. A presença dos patógenos indica que o reuso da ALF em ETA convencionais ou o descarte em mananciais sem um tratamento prévio, pode representar problemas de contaminação. A adaptação dos métodos de Boni de Oliveira (2012) e Keegan et al. (2008), também repercutiram em porcentagens de recuperação expressivas para a amostra de resíduo sedimentado, sendo de: 41 ± 35 % para oocisto de C. parvum e 11 ± 70 % para cisto de Giardia spp., e 38 ± 26 % para oocisto de C. parvum e 26 ± 13 % para cisto de Giardia spp., respectivamente. A análise estatística não resultou em diferença significativa entre estes dois métodos, entretanto, as elevadas recuperações indicam que estes métodos podem ser melhor avaliados em pesquisas futuras.
Title in English
Evaluation of several methods for the detection of Giardia spp. cysts and Cryptosporidium parvum Oocysts in wastes produced after high- turbidity water treatment
Keywords in English
Cryptosporidium parvum
Giardia spp.
immunomagnetic separation – IMS
jar test
Polyaluminum Chloride – PACl
protozoa
waste of water treatment
Abstract in English
This dissertation addresses the evaluation of several methods for the detection of Giardia spp. cysts and Cryptosporidium parvum oocysts in wastes produced after a high-turbidity water treatment, according to Method 1623.1 from USEPA (2012). Coagulant polyaluminium chloride - PACl was used in jar test experiments (coagulation/flocculation, sedimentation and filtration ). The Immunomagnetic Separation - IMS technique was applied to all methods. The calcium carbonate flocculation (CCF) method, developed by Vesey et al. (1993) and adapted by Feng et al. (2011 ), was applied to sludge samples in this research and was the best method tested, with 68% ± 17 % and 42 % ± 7,00 % recoveries for C. parvum oocysts and Giardia spp. cysts, respectively. On the other hand, the percentage recovery of (oo)cysts for filter backwash water samples was lower than 1 % and no suitable method could be detected. The presence of pathogens represents contamination risks for water sources and the reuse of filter backwash water may be a problem to conventional water treatment plants. The application of Boni de Oliveira (2012) and Keegan et al. (2008) methods, adjusted to this study, also resulted in significant percentage recoveries for the sludge samples, with 41 ± 35 % for C. parvum oocyst and 11 ± 70% for cyst Giardia spp., and 38 ± 26% for oocyst C. parvum and 26 ± 13% for cyst Giardia spp., respectively. The statistical analysis showed no significant differences between the two methods, however, such high recoveries indicate they should be better evaluated in future research.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
GUILHERME_GIGLIO.pdf (2.78 Mbytes)
Publishing Date
2016-05-12
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.