Disertación de Maestría
DOI
https://doi.org/10.11606/D.18.2007.tde-06012008-125103
Documento
Autor
Nombre completo
Silvia Sônia da Silva
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2007
Director
Tribunal
Povinelli, Jurandyr (Presidente)
Daniel, Luiz Antonio
Rezende, Maria Olímpia de Oliveira
Título en portugués
Aplicação de radiação UV para desinfecção de efluente da associação de reator UASB e biofiltro aerado submerso
Palabras clave en portugués
Custos de desinfecção
Desinfecção por UV
Inativação de microrganismos indicadores
Resumen en portugués
Essa pesquisa investigou e interpretou aspectos relevantes da desinfecção por radiação ultravioleta (UV) na inativação de microrganismos indicadores. O efluente sanitário foi proveniente de tratamento anaeróbio (Reator UASB), seguido de Biofiltro Aerado Submerso, em escala real. A pesquisa foi dividida em duas etapas, sendo que na primeira foi dado destaque ao estudo das características operacionais da unidade ultravioleta. Na segunda etapa da pesquisa objetivou-se o estudo da resistência de diferentes microrganismos indicadores à radiação ultravioleta e das possíveis correlações entre as variáveis testadas. Os resultados obtidos na primeira etapa da pesquisa forneceram indicativos de que a limpeza das lâmpadas emersas pode ser feita em períodos superiores a 2 meses, devendo-se levar em consideração também a fragilidade do sistema. A limpeza do canal de desinfecção não teve relação com a eficiência de desinfecção. A operação de unidades UV é relativamente simples desde que haja treinamento dos operadores e condições ergonômicas favoráveis ao trabalho dos mesmos. O custo operacional situou-se na faixa de 0,006 R$/'M POT.3' de esgoto desinfetado e o custo de energia elétrica foi de 0,07 R$/'M POT.3' de esgoto desinfetado. As eficiências máximas de desinfecção encontradas na segunda etapa da pesquisa foram de 100% para Colifagos, 99,999% para CF (Coliformes Fecais) e 99,993% para CT (Coliformes Totais), o que demonstra que a ordem decrescente de resistência desses organismos é CT > CF > Colifagos. Os resultados indicaram que houve pouca variação da eficiência de inativação para as três lâminas de esgoto testadas (3 cm, 4 cm e 5 cm) o que sugere que a unidade é capaz de atender aumentos moderados de vazão, confirmando os pressupostos adotados no seu dimensionamento. Os dados obtidos a partir do ensaio hidrodinâmico indicaram que o reator de desinfecção testado comporta-se como um sistema composto de um reator pistonado ideal com presença de curtos circuitos hidráulicos.
Título en inglés
UV radiation application for sewer disinfection of the UASB reactor association with aerated submerged biofilter (ASB)
Palabras clave en inglés
Disinfection costs
Indicator microorganism's inactivation
UVR disinfection
Resumen en inglés
This research has investigated and interpreted relevant aspects of disinfection by ultraviolet radiation (UVR) in the inativation of indicator microorganisms' inactivation. The sanitary effluent was provided by anaerobic treatment (UASB reactor), followed by aerated submerged biofilter (ASB), on a real scale. This research was divided into two stages, whereas in the first stage, operational characteristics of the ultraviolet unit studies were highlighted. The aim of the second stage of the research was the resistance of different indicator microorganisms to ultraviolet radiation study and the possible relation among variables tested. Results obtained in the first stage of the research have provided indication that the cleaning of submerged lamps may be done in periods longer than two months, however the fragility of the system must be considered. Disinfection channel cleaning should not be related to the disinfection efficiency. The operation of UV units is relatively simple, as long as the operators are trained and work under favorable ergonomic conditions. The operational cost was set at 0.006 R$/'M POT.3' of disinfected sewer system and the electrical energy cost was set at 0.07 R$/'M POT.3'. The maximum efficiency found on the disinfection of the research second stage were 100% for Coliphages, 99.999% for FC and 99.993% for TC, which demonstrates that the resistance decreasing order of these organisms is TC > FC > Coliphages. Results indicated that there was a low inactivation efficiency variation for the three tested sewer samples (3 cm, 4 cm and 5 cm), which suggests that the unit is capable of serving moderate increase of flow, confirming adopted predictions in its dimensioning. Information obtained from the hydrodynamic test indicated that the tested disinfection reactor behaves as a compound system of an ideal piston reactor with hydraulic short circuits.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
dissertacao.pdf (1.22 Mbytes)
Ficha.pdf (40.30 Kbytes)
Fecha de Publicación
2008-02-18
 