Thèse de Doctorat
DOI
https://doi.org/10.11606/T.18.2006.tde-17012011-112250
Document
Auteur
Nom complet
Geraldo Dantas Silvestre Filho
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2006
Directeur
Jury
Carvalho, Jonas de (Président)
Albuquerque, Eder Lima de
Claro Neto, Salvador
Purquerio, Benedito de Moraes
Tita, Volnei
Titre en portugais
Projeto e análise estrutural de haste femoral de implante de quadril em material compósito polimérico
Mots-clés en portugais
Análise estrutural
Comportamento mecânico
Haste femoral
Materiais compósitos poliméricos reforçados
Modelo de material
Projeto
Simulação computacional
Resumé en portugais
Neste trabalho propõe-se o projeto e a análise estrutural de uma haste femoral de implante de quadril em material compósito polimérico. No trabalho, realizaram-se algumas etapas com a finalidade de obter parâmetros confiáveis de comportamento do material, visando à consistência dos resultados numéricos e experimentais. Primeiramente, faz-se um levantamento bibliográfico sobre o comportamento mecânico dos materiais compósitos poliméricos reforçados, como também dos critérios de falha existentes para este tipo de material. Em seguida, apresentam-se as etapas experimentais com a descrição dos procedimentos de fabricação dos corpos-de-prova e os resultados obtidos a partir dos ensaios quase-estáticos de tração do poliuretano derivado de óleo de mamona. A etapa seguinte foi desenvolver um dispositivo de ensaio monotônico quase-estático para a haste femoral em poliuretano com o objetivo de levantar a curva força-deslocamento seguindo as especificações das normas ISO 7206-3 e ISO 7206-4. Com base nos resultados experimentais obtidos, foi possível propor um reforço estrutural, na forma de tubo, na haste femoral em poliuretano e adotar uma análise de falha progressiva para determinar o seu comportamento mecânico. Para esta finalidade foi implementado um modelo de material em sub-rotina FORTRAN, compilada em conjunto com um programa de elementos finitos (ABAQUS). Concluiu-se, que o modelo de material implementado e o reforço estrutural proposto para a haste femoral traz contribuições inovadoras, visto que se pode prever com mais precisão o comportamento mecânico da haste femoral reforçada com o tubo em material compósito polimérico.
Titre en anglais
Design and structural analysis of hip implant femoral stem in polymeric composite materials
Mots-clés en anglais
Computational simulation
Design
Femoral stem
Material model
Mechanical behavior
Reinforced polymeric composite materials
Structural analysis
Resumé en anglais
A design and structural analysis of a femoral stem using a polymeric composite material is proposed in this work. The work had some steps in order to achieve trusty parameters for the material behavior aiming the consistence of numerical and experimental results. In the first step, a bibliographic review of mechanical behavior of reinforced polymeric composite materials as well as failure criterion was done. Following experimental steps are presented with specimen manufacturing procedure description and the results obtained from quasi-statics tension tests of polyurethane derivated from castor oil. The next step was the development of a monotonic quasistatic test device for the polyurethane femoral stem aiming to determine the forcedisplacement curve according to ISO 7206-3 and ISO 7206-4 standards. Considering the experimental results obtained it was possible to propose a structural reinforcement, which consists on a tube, in the polyurethane femoral stem and to adopt a progressive failure analysis in order to determine its mechanical behavior. A material model using FORTRAN sub-routine was developed and compiled joint with a finite element program (ABAQUS). The conclusion is that the model developed and the structural proposed reinforcement for the femoral stem bring innovation for this contribution once it is possible to preview accurately the mechanical behavior of the reinforced femoral stem with tube in polymeric composite material.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2011-02-07
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.