Richard Garcia Alves de Mello
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2000
Supervisor
Committee
Saiz Jabardo, José Maria (President)
Hernandez Neto, Alberto
Oliveira Junior, Silvio de
Title in Portuguese
Modelo de simulação e análise teórico-experimental de serpentinas resfriadoras e desumidificadoras de ar
Keywords in Portuguese
Coeficiente de transferência de calor
Simulação
Trocadores de calor
Abstract in Portuguese
Em sistemas frigoríficos de compressão a vapor, o evaporador é o equipamento responsável direto pela retirada de calor de ambientes refrigerados. Por esta razão, este componente é a fonte de investigação do presente estudo, o qual teve por objetivo principal a busca por alternativas para a melhoria de desempenho térmico em sistema frigoríficos. Isto posto, o trabalho foi desenvolvido em três frentes de estudo, as quais encontram-se interligadas entre si: desenvolvimento de programa de simulação de serpentinas resfriadoras; realização de ensaios para determinação das capacidades de trocadores de calor; e revisão bibliográfica circunstanciada do coeficiente de transferência de calor do lado do ar. O programa de simulação desenvolvido, o qual tomou como base o modelo proposto por Rich, mostrou-se ser uma ótima ferramenta de trabalho, tanto no meio acadêmico como no industrial. Como conseqüência da elaboração do programa, fez-se uso de correlações já existentes para determinação dos coeficientes de transferência de calor do lado do refrigerante, Bo Pierre, e do lado do ar, McQuiston, sendo esta última escolhida a partir de um sumário de correlações levantadas quando no estudo dos coeficientes de transferência de calor descritos acima. Para que o programa fosse validado como ferramenta de trabalho, foram realizadas simulações dos ensaios das serpentinas testadas e seus resultados confrontados. Tais resultados apresentam uma adequada concordância,possibilitando validar o programa. Os ensaios foram realizados segundo recomendações da norma ASHRAE 25/1992. Dos dados obtidos nos testes, também foi proposto uma correlação para o fator j-Colburn para superfícies secas; no entanto, tratou-se apenas de especular acerca de seu comportamento com as demais correlações, as quais obtiveram boa concordância.
Title in English
Model of simulation and analysis of cooling and air dehumidifuing coils
Keywords in English
Heat exchangers
Heat transfer coefficient
Simulation
Abstract in English
In refrigerating systems of compression to vapour, the evaporator is the direct responsible equipment for remove of heat of cooling environments. In this way, the component is the source of investigation of the present study, which had for main objective the search for alternatives to improvement the performance thermal in refrigeration systems. The research was developed in three studies fronts, that are connected each other: development of program of simulation of cooling coils; tests to find the performance of heat exchange; and revision bibliographical of the coefficient of heat transfer of air. The developed simulation program, based in the Rich's model, it showed to be a good work tool, as in the academic, as in the industrial behaviour. As consequence of the elaboration the program, it was used existents correlations to calculation the coefficients of refrigerant heat transfer, Bo Pierre, and to air, McQuiston, the last one was choose from a correlation's summary. Same simulations were made to validated the program of the tested serpentines and the results were confronted. Such results presented an appropriate agreement that contributed to validate the program. The tests were accomplished according to recommendations of the norm ASHRAE 25/1992. One correlation was proposed for the factor j-Colburn for dry surfaces in base of the testes results; however, the purpose was to speculated its behaviour with the other correlations, which obtained good agreement.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2017-04-07
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.