• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.18.2016.tde-30032016-151513
Documento
Autor
Nombre completo
Humberto Correia Lima Júnior
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2003
Director
Tribunal
Giongo, José Samuel (Presidente)
Fernandes, Gilson Battiston
Guimarães, Giuseppe Barbosa
Proença, Sergio Persival Baroncini
Ramalho, Marcio Antonio
Título en portugués
Avaliação da ductilidade de pilares de concreto armado, submetidos à flexo-compressão reta com e sem adição de fibras metálicas
Palabras clave en portugués
Concreto de alta resistência
Confinamento
Excentricidade de força
Fibras metálicas
Pilar
Resumen en portugués
Este trabalho tem como objetivo investigar o comportamento pós-pico de pilares com concretos de alta resistência confinados com e sem adição de fibras metálicas, submetidos à flexo-compressão. Para tanto, realizou-se inicialmente uma extensa revisão bibliográfica sobre o tema, na qual, elencaram-se os principais fatores que influenciam o comportamento pós-pico desses elementos estruturais. Em seguida, desenvolveram-se estudos paramétricos com o intuito de estabelecer os modos de influência de cada fator. Com base nesses estudos preliminares, um programa experimental, dividido em duas fases, foi proposto. Na primeira fase, ensaiaram-se vinte e seis pilares de concreto armado e 14 pilares de concreto simples. Três fatores foram estudados: a taxa de adição de fibras metálicas, a taxa de armadura transversal e a resistência à compressão do concreto. Os pilares possuíam seções transversais quadradas com dimensões 15 cm x 15 cm e altura de 50 cm e foram ensaiados à compressão centrada com controle de deslocamento. Observou-se que os três fatores analisados influenciam diretamente a ductilidade desses elementos estruturais e que, por meio de adição de fibras metálicas, é possível garantir índices de ductilidade aceitáveis para os pilares com concreto de alta resistência. Outrossim, analisando-se os diagramas força vs. deformação dos pilares, observou-se que para o primeiro pico de força, toda a seção resiste a esforços de compressão e que a adição de fibras melhora o trabalho conjunto entre o cobrimento e o núcleo do pilar. Finalizando esta fase, propuseram-se modificações para o modelo para concreto confinado de Cusson e Paultre (1995), de modo que, permitisse ao mesmo modelar o comportamento do concreto confinado com e sem adição de fibras metálicas. Na segunda fase do programa experimental, quinze pilares de concreto armado foram ensaiados a compressão excêntrica. Essa fase teve como objetivo investigar a influência da excentricidade, da taxa de armadura transversal e da taxa de adição de fibras metálicas no comportamento pós-pico desses elementos estruturais. Os pilares, nessa fase, possuíam seção transversal quadrada com dimensões de 15 cm x 15 cm e altura de 170 cm. Para realização dos ensaios foi confeccionado um par de rótulas unidirecionais, as quais apresentaram excelente desempenho, conseguindo transferir integralmente o momento externo aplicado ao pilar. Observou-se que, tanto a flambagem das barras da armadura longitudinal, quanto a perda de massa de concreto nesses pilares ocorrem de modo bem mais crítico que nos pilares submetidos à compressão centrada. Constatou-se, ainda, que quando os valores dos três fatores analisados são elevados, a ductilidade desses elementos estruturais é melhorada. Finalmente, foi observado que o efeito da flexão faz com que as tensões de confinamento se distribuam de modo diferenciado dentro da seção transversal dos pilares; contudo, observou-se que a tensão de confinamento na região comprimida da seção transversal pouco é modificada.
Título en inglés
Evaluation of the reinforced concrete columns' ductility, under combined axial load and bending, with or not steel fibres addition
Palabras clave en inglés
Column
Confinement and load eccentricity
High strength concrete
Steel fibre
Resumen en inglés
This thesis aims to investigate the ductility of high strength concrete columns, with confinement and/or with steel fibre addition, under combined axial load and bending. For this, an extensive survey was performed, and the main factors, which influence the column ductility, were pointed out. Then, parametric studies were done, aiming to establish the mode of influence of each factor. Based on these preliminaries studies, an experimental investigation, divided in two steps, was proposed. In the first part, twenty-six reinforced concrete columns and fourteen concrete columns were tested and three factors were analysed: the ratio of fibre addition, the transversal reinforcement ratio and the concrete compressive strength. The columns have 15 cm x 15 cm square cross section and were 50 cm high. They were tested under concentric load with displacement control. It was observed that all factors interfere in the columns' ductility, and that, by adding fibre in the concrete, is possible to provide acceptable ductility index to high strength concrete columns. The load vs. column strain diagrams were studied and it was verified that for the first load peak, all the column cross section resists the axial load. Besides that, it was observed that the fibre addition improves the work together between the cover and the column core. Finally, several modifications to the concrete confinement model of Cusson and Paultre (1995) were proposed to allow this model to analyse the compressive behaviour of the confined concrete with or/not fibre addition. In the second part of the experimental program, fifteen reinforced concrete columns were tested under eccentric load. The effects of the load eccentricity, the ratio of steel fibre addition and the transversal reinforcement ratio on the column ductility were investigated. The columns have 15 cm x 15 cm square cross section and were 170 cm high. A pair of unidirectional hinges was design, which presented exceptional performance, transferring integrally the external applied moment to the columns. A most critical model of longitudinal reinforcement buckling and mass lost was observed. In addition, it was verified that when the values of all factors were increased, the column ductility was improved. Finally, a different distribution mode of the confinement pressure on the column cross section was observed, when combined axial load and bending is applied. Nevertheless, the confinement pressure on the compressive region of the column cross section is not modified.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2016-03-30
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.