Tesis Doctoral
DOI
https://doi.org/10.11606/T.18.2016.tde-30032016-144646
Documento
Autor
Nombre completo
Edna das Graças Assunção Freitas
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2001
Director
Tribunal
Calil Junior, Carlito (Presidente)
Freire, Wesley Jorge
Malite, Maximiliano
Negrisoli, Ari Antonio
Savassi, Walter
Título en portugués
Estudo teórico e experimental das pressões em silos cilíndricos de baixa relação altura/diâmetro e fundo plano
Palabras clave en portugués
Parâmetro K
Pressões
Silos de baixa relação altura/diâmetro
Resumen en portugués
A armazenagem em fazenda necessita ser expandida de modo a propiciar um melhor equilíbrio de fluxos e funções entre as etapas da rede armazenadora. No Brasil, embora não se disponha de números exatos, sabe-se que armazenagem na fazenda é mínima, sendo estimada em torno de 4% a 7%, dependendo da região. Em geral, os silos utilizados para a armazenagem em fazenda apresentam baixa relação entre a altura do silo e o seu diâmetro ou lado (0,75 a 1,5) e fundo plano. Podem ser construídos com os mais diversos materiais, como concreto, madeira, argamassa armada etc., mas a predominância é a utilização de silos metálicos em chapa de aço ondulada. Apesar da intensa utilização destas unidades em todo o mundo, e serem as mais produzidas pela indústria, a previsão das pressões devidas ao produto armazenado é ainda divergente entre os pesquisadores e normas existentes. Este trabalho foi realizado em duas etapas: teórica e experimental. Na parte teórica, deu-se ênfase à análise comparativa das principais teorias e normas estrangeiras. Na parte experimental, foram feitos ensaios diretos em um silo protótipo com relação h/d=0,98 e um silo piloto para relações h/d=0,98, 1,25 e 1,49, ambos de chapa de aço ondulada, para obtenção das pressões horizontais na parede e verticais no fundo plano. Com base nos resultados experimentais propõe-se modelos empíricos para a determinação das pressões horizontais e verticais no fundo plano do silo para esse tipo de unidade armazenadora. Também determinou-se experimentalmente o valor do parâmetro K, concluindo-se que a formulação de Hartmann é a mais indicada para silos metálicos de chapa de aço ondulada.
Título en inglés
Theoretical and experimental study of loads in squat silos and flat bottom
Palabras clave en inglés
Parameter K
Pressures
Silos of low relationship height/diameter
Resumen en inglés
The farm storage must be expanded in order to offer a better balance of flows and functions among the stages of the storage system. In Brazil, it is known that storage in the farms is only about 4% to 7%, depending on the region. In general, the silos used for farm storage presents low ratio between the height of the silo and its diameter or side (0,75 to 1,5) and flat bottom. They can be built with different structural materials, as concrete, wood, ferrocement, etc., but the material predominance is corrugated steel. In spite of the intense use of these units all over the world, and its industry production, the pressures due the stored product is still divergent between the researchers and existent codes. This work was accomplished in two stages: theoretical and experimental. The theoretical part corresponds to the comparative analysis of the main theories and foreign codes. The experimental part corresponds to load tests using pressure cells in a silo prototype of relationship h/d=0,98 and a pilot silo for relationships h/d=0,98, 1,25 and 1,49, both of corrugated steel, for obtaining of the horizontal wall pressures and vertical pressures in the flat bottom. Based in the experimental results empiric models for the determination of the horizontal and vertical pressures in the bottom are proposed. The value of the parameter K, was also experimentally determined and the results showed that the formulation of Hartmann is the most suitable for metallic silos of corrugated steel plates.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.