Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.18.2018.tde-24042018-120327
Document
Auteur
Nom complet
Regina Maria dos Santos Carmo
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 1995
Directeur
Jury
Corrêa, Márcio Roberto Silva (Président)
França, Ricardo Leopoldo e Silva
Venturini, Wilson Sérgio
Titre en portugais
Efeitos de segunda ordem em edifícios usuais de concreto armado
Mots-clés en portugais
Edifícios altos - instabilidade global
Efeitos de segunda ordem
Resumé en portugais
Neste trabalho são estudados os parâmetros de verificação do estado limite de deformações excessivas (a relação flecha-altura-a/H) e da estabilidade global (o parâmetro α e o coeficiente γz) das estruturas de edifícios. Através da utilização de exemplos de estruturas de trinta (30) edifícios usuais de concreto armado, estabelece-se uma relação entre esses parâmetros, objetivando propiciar ao projetista de estruturas condições de avaliar a eficiência e o grau de confiabilidade de cada um deles. São também discutidos e comparados alguns dos procedimentos usuais para realizar uma análise global de segunda ordem das estruturas. Nesta análise deve-se levar em conta tanto a não-linearidade física (NLF) quanto a geométrica (NLG) e, para tanto, são adotados métodos rigorosos e aproximados. Quer-se com isso, principalmente, analisar o processo simplificado como suficiente para se obter os esforços finais de segunda ordem, uma vez que se pretende incluir tal procedimento na norma brasileira NB-1, atualmente em fase de revisão.
Titre en anglais
Second order effects in usual reinforced concrete buildings
Mots-clés en anglais
Second order effects
Tall buildings - global instability
Resumé en anglais
In this work, a servicebility pararneter (displacement-height ratio - a/H) is studied, as well as the global stability parameters of building structures (α and γz stability coefficients). By analyzing thirty (30) actual reinforced concrete building structures, a relationship among these parameters (α, γz and a/H) is achieved aiming to demonstrate to the building structure designers their level of efficiency and reliability for practical purposes. Some standard procedures for global second order structure analysis are also discussed with comparison among them. In this analysis, the material and the geometric non-linearities have to be considered and for that one can adopt approximated and accureted methods. Mainly, the interest is to verify the possibility of using the simplified method as a proper tool to compute the final second order efforts of buildings, once this procedure could be included into the Brazilian Code, NB-1, which is being revised.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2018-04-24
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.