• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.18.2012.tde-13082012-083304
Documento
Autor
Nombre completo
Luiz Álvaro de Oliveira Júnior
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2012
Director
Tribunal
El Debs, Mounir Khalil (Presidente)
Araújo, Daniel de Lima
Figueiredo, Antonio Domingues de
Sousa, José Luiz Antunes de Oliveira e
Teixeira, Pedro Wellington Gonçalves do Nascimento
Título en portugués
Ligação viga-pilar em elementos pré-moldados de concreto solidarizados por concreto reforçado com fibras de aço: análises estática e dinâmica
Palabras clave en portugués
Concreto
Concreto com fibras de aço
Ligação viga-pilar
Pré-moldados
Resumen en portugués
No presente trabalho, utiliza-se concreto com fibras de aço, traspasse de armaduras e chaves de cisalhamento para desenvolver uma ligação viga-pilar capaz de resistir a ações cíclicas e dinâmicas e que possa ser empregada na pré-moldagem de estruturas de casas de força de usinas hidrelétricas. Para atingir este objetivo, inicialmente foram realizados ensaios de caracterização dos materiais, cujos resultados mostraram aumentos de 34% na resistência à tração na flexão, 16% na resistência à compressão e 33% na tenacidade, comprovando os efeitos benéficos das fibras de aço nas propriedades mecânicas do concreto. Em seguida, foram realizados ensaios de tração em tirantes, cujos resultados sugeriram que um comprimento de 15Ø é suficiente para que a emenda desenvolva as tensões de aderência de modo adequado; e ensaios de cisalhamento, cujos resultados mostraram que a ligação viga-pilar resiste a tensões de cisalhamento direto de até 0,77 MPa. Na sequencia, foram realizados ensaios cíclicos em dois modelos cruciformes para caracterização da ligação (um monolítico e outro de concreto pré-moldado, o qual empregava concreto com 1% de fibras na região da ligação), sendo o carregamento aplicado em cinco níveis de força, cada um com dez ciclos de carregamento e descarregamento. Os resultados desses ensaios mostraram que a ligação do modelo em concreto pré-moldado apresentou 85% da resistência do modelo monolítico e ruptura governada por flexão. Por fim, os ensaios dinâmicos foram realizados nos modelos cruciformes em três diferentes situações (íntegros, fraturados e após ruptura da ligação) para estimar o coeficiente de amortecimento, o qual sofreu uma redução de 31% após o ensaio cíclico. Simulações computacionais foram realizadas para complementar a investigação realizada neste trabalho. Elas mostraram representação aceitável da rigidez, mas não da resistência do modelo.
Título en inglés
Beam-column connection in precast concrete structures using steel fiber reinforced concrete
Palabras clave en inglés
Beam-column connection
Concrete
Precast concrete structures
Steel fiber reinforced concrete
Resumen en inglés
In the present work, steel fiber reinforced concrete, splicing bars and shear keys are used in order to develop a beam-column connection able to support cyclic and dynamic loadings and which can be used in precasting power houses structures of power plants. To achieve this goal, tests were carried out to characterize the materials, which showed increases of 34% in flexural tensile strength, 16% in compressive strength and 33% in toughness factor, confirming the beneficial effects of steel fibers in mechanical properties of the concrete. Then, tensile tests were carried out on rods, whose results suggested that a length of 15Ø can assure appropriate development of bond stresses through the splice; and shear tests, whose results showed that the beam-column connection resists to shear stresses of up to 0,77 MPa on shear key. After, cyclic tests were performed in two cruciform models in order to characterize the beam-column connection (one monolithic and the other precast concrete, which employed 1% steel fiber reinforced concrete in connection region, being the loading applied in five loading levels, each one in 10 cycles of loading and unloading. Results of these tests showed that precast beam-column connection presented 85% of the strength presented by the monolithic model and bending failure. Finally, dynamic tests were performed in cruciform models in three different situations (uncracked, cracked and after failure) for estimating the damping ratio, which was reduced by 31% after cycles. Computer simulations were performed to complement the research developed in this work. They showed acceptable representation of stiffness, but the strength of the model.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2012-08-21
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.