• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.18.2014.tde-11122014-112929
Document
Author
Full name
Igor Vinicius Santana
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2014
Supervisor
Committee
El Debs, Ana Lúcia Homce de Cresce (President)
Barbosa, Mônica Pinto
Haach, Vladimir Guilherme
Title in Portuguese
Estudo da influência das fibras metálicas no comportamento da aderência entre barras de aço e concretos de diferentes classes de resistência
Keywords in Portuguese
Aderência aço-concreto
Concreto de alta resistência
Ensaio de arrancamento
Fibras de aço
Abstract in Portuguese
O emprego e o funcionamento do concreto armado como material estrutural só é possível devido à aderência entre o aço e o concreto. A aderência atua como um mecanismo de transferência de forças, além de garantir a compatibilidade de deformações entre a armadura e o concreto circundante. Inúmeros fatores influenciam no seu comportamento, desde as variáveis relacionadas aos componentes fundamentais do material: como o diâmetro da barra de aço e a resistência à compressão do concreto, até as variáveis que não são essenciais para a sua mobilização como é o caso das fibras metálicas. Sendo assim, buscou-se com o presente trabalho estudar o comportamento da aderência entre barras de aço e concretos de resistência convencional e de alta resistência com adição de fibras metálicas. Para tanto foram pesquisados alguns dos modelos teóricos que se dispõem a representar o comportamento da aderência, como os prescritos pela Associação Brasileira de Normas Técnicas (ABNT) NBR 6118:2003 e o seu projeto de revisão, pela International Federation for Structural Concrete (fib) Bulletin 65: Model Code 2010, pelo American Concrete Institute ACI 318:2014 e os modelos propostos por alguns autores encontrados na bibliografia específica, com posterior comparação dos seus resultados com os resultados obtidos experimentalmente mediante ensaios de arrancamento baseado no procedimento padrão proposto pela RILEM-FIP-CEB (1973). Foram empregadas no estudo experimental, barras de aço com diâmetros de 10 mm e 16 mm em corpos-de-prova moldados com concretos de resistências à compressão de 30 MPa, 60 MPa e 90 MPa. As fibras metálicas utilizadas possuíam comprimentos de 13 mm e 25 mm nos teores volumétricos de 0, 1% e 1,5%, além da hibridização para um volume de 1%. Os resultados experimentais demonstraram que para os teores utilizados, as fibras metálicas não influenciaram significativamente os parâmetros quantitativos da aderência como a tensão última de aderência e o seu respectivo deslizamento, porém foram decisivas para o tipo e a forma da ruptura predominantemente dos concretos de alta resistência. Da analise comparativa entre os resultados experimentais e teóricos verificou-se que os modelos do CEP-FIB (2010) e de Huang et al. (1996), com destaque para este último, foram os modelos que melhor representaram o comportamento da curva tensão de aderência versus deslizamento. Em relação à resistência de aderência de cálculo o ACI 318:2014 foi o código que apresentou os resultados mais conservadores e o código brasileiro, mesmo em seu projeto de revisão, foi o que apresentou resultados com menores diferenças em relação aos valores experimentais.
Title in English
Study of the influence of steel fibers on the behavior of bond between steel reinforcement and concretes of different strength classes
Keywords in English
Bond steel-concrete
High strength concrete
Pull-out test
Steel fiber
Abstract in English
The use and operation of reinforced concrete as a structural material is only possible due to the bond between reinforcement and concrete. The adherence acts as a mechanism to transfer forces and ensures the compatibility of deformations between the reinforcement and the surrounding concrete. Several factors influence its behavior, since the variables related to the fundamental components of the material: as the diameter of the reinforcement and the compressive strength of the concrete, as the variables that are not essential for its mobilization as the steel fibers. Thus, it sought with this present work to study the behavior of bond between steel reinforcement and conventional strength concrete and high strength concrete with addition of steel fibers. For that, some of the analytical models that seek to represent the behavior of bond were researched as prescribed by the Brazilian Association of Technical Standards (ABNT) NBR 6118:2003 and its project review, by the International Federation for Structural Concrete (fib) Bulletin 65: Model Code 2010, by the American Concrete Institute ACI 318:2014 and models proposed by some authors found in the research literature, with subsequent comparison of its results with those obtained experimentally by pullout tests based on the standard test proposed by RILEM-CEB-FIP (1973). Steel reinforcements with diameters from 10 mm to 16 mm in specimens molded with concretes with compressive strength of 30 MPa, 60 MPa and 90 MPa were used. The steel fibers used had lengths of 13 mm and 25 mm in volumetric rates of 0,1% and 1,5%, in addition to hybridization to a volume of 1%. The experimental results showed that for the rates used, the steel fibers had no significant influence on quantitative parameters of the adherence as the bond strength and its respective slip, but they are decisive for the type and mode of failure of high-strength concrete. The comparative analysis between experimental and theoretical results showed that the models of CEP-FIB (2010) and Huang et al. (1996), especially the latter, were the models that best represented the behavior of the bond stress-slip relationship. Regarding to the design bond strength, the ACI 318:2014 was the model code that presented the most conservative results and the Brazilian code, even in its draft version, presented the results with minor differences from the experimental values.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2015-01-07
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.