Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.18.2008.tde-11062008-112706
Document
Auteur
Nom complet
Rômulo da Silva Farias
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2008
Directeur
Jury
El Debs, Ana Lucia Homce de Cresce (Président)
Malite, Maximiliano
Requena, João Alberto Venegas
Titre en portugais
Estudo teórico-experimental do efeito da laje na transferência de forças em ligações viga-pilar misto preenchido
Mots-clés en portugais
Aderência aço-concreto
Estruturas mistas
Ligação mista
Ligação viga-pilar
Pilares mistos preenchidos
Resumé en portugais
Este trabalho tem como objetivo analisar a influência da laje de concreto armado em uma ligação viga-pilar misto mediante um estudo experimental e uma modelagem numérica. A ligação considerada é constituída por uma viga de aço unida a um pilar misto preenchido através de barras rosqueadas que trabalham como parafusos passantes. Esse tipo de ligação já foi investigado em trabalhos anteriores, mediante análise experimental em modelos que não incluíam a laje, resultando em uma indesejável ruptura dos parafusos. A análise da ligação completa, com a presença da laje de concreto tornando a ligação uma ligação mista, além de ser mais realista, melhora as características de resistência e rigidez do modelo, além de tornar mais dúctil o seu comportamento. Para isso foram analisados três modelos experimentais que se diferenciam pela ausência ou tipo de conector de cisalhamento presente na região interna do pilar misto. Os resultados obtidos mostraram que a ruptura da ligação passou a ser determinada pela laje, associada ao escoamento da armadura longitudinal sem que a ligação viga-pilar fosse comprometida. Para a análise numérica foi utilizado o pacote computacional DIANA®, baseado no método dos elementos finitos. Os modelos numéricos foram desenvolvidos e calibrados pelos resultados experimentais, produzindo resultados bastante satisfatórios. Finalmente foi realizada uma análise numérica paramétrica variando a armadura longitudinal da laje e a resistência do concreto com o objetivo de se entender melhor a influência desses parâmetros no comportamento da ligação investigada.
Titre en anglais
Experimental and theorical analysis of slab effect on the force transfer strength of steel beam to concrete filled columns connection
Mots-clés en anglais
Beam-column connection
Composite connection
Concrete filled collumns
Resumé en anglais
The main objective of this work was to analyze the contribution of the concrete slab for the behavior of a steel beam-concrete filled composite column connection through an experimental program and also a numerical modeling. The considered connection was constituted of steel beams connected to a concrete filled tubular column of rectangular cross section by means of passing bars. This type of connection was studied before through an experimental analysis of connections that did not include the slab, resulting in failure of the passing bars. In the present study, the presence of the slab is considered, turning the connection a composite one. The studied model is more representative of the real structure, and also improves the resistance and the stiffness of the connection, turning the behavior more ductile. Three specimens were tested, where the studied variable was the type of shear connector, angles or stud-bolts, and one specimen without connectors as a reference. The obtained results showed that the failure was determined by the slab, associated to the yielding of the longitudinal reinforcement, without affecting the beam column connection. The finite element based software DIANA® was used to the numerical analysis. The numerical models were developed and calibrated by the experimental results, producing a good agreement. Finally, a parametric analysis was done, varying the slab longitudinal reinforcement and the concrete strength in order to better understand the influence of these parameters in the behavior of the studied connection.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2008-06-16
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.