• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.18.2016.tde-06042016-112204
Document
Auteur
Nom complet
Patricia Tavares de Souza
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2016
Directeur
Jury
El Debs, Ana Lúcia Homce de Cresce (Président)
Araújo, Daniel de Lima
De Nardin, Silvana
Titre en portugais
Análise teórica e experimental de pisos mistos de pequena altura compostos por vigas metálicas e lajes alveolares de concreto
Mots-clés en portugais
Análise experimental
Conector tipo pino com cabeça
Estruturas mistas
Laje alveolar
Piso misto de pequena altura
Resumé en portugais
No mercado mundial existe uma visível tendência de tornar as obras mais industrializadas e racionalizadas com o objetivo de reduzir os desperdícios, acelerar a velocidade de execução das obras e garantir maior qualidade às mesmas. A adoção de elementos estruturais com certo grau de industrialização pode trazer benefícios em relação aos custos, à mão de obra, ao tempo de execução e ao impacto ambiental. Neste contexto, as estruturas mistas de aço e concreto satisfazem essa necessidade, pois tanto os elementos de aço quanto os elementos de concreto podem ser pré-fabricados, ficando apenas as etapas de içamento e montagem a serem realizadas na obra, reduzindo o uso de fôrmas e escoramentos. Os pisos mistos de aço e concreto de pequena altura caracterizam-se pelo embutimento da laje de concreto na altura do perfil de aço, sendo a principal vantagem, em relação ao piso misto convencional, a redução da altura total do composto. Portanto, este trabalho tem como objetivo analisar o comportamento de pisos mistos de aço e concreto de pequena altura com laje alveolar em concreto protendido por meio de ensaios de cisalhamento direto (push-out test) e de flexão. Na solução proposta, a transferência de esforços entre o perfil de aço e a laje alveolar foi feita por meio de conectores tipo pino com cabeça e concreto moldado no local. Os resultados demonstraram-se promissores em termos de comportamento do piso misto de pequena altura, aumentando significativamente a rigidez do sistema em relação à viga de aço isolada. Em complemento, foi desenvolvida uma simulação numérica dos modelos físicos ensaiados utilizando o pacote computacional DIANA®, fundamentado no método dos elementos finitos, na qual o modelo numérico representou adequadamente o comportamento dos pisos mistos de pequena altura, permitindo análises paramétricas.
Titre en anglais
Theoretical and experimental analysis of slim floor systems composed by steel beam and concrete hollow core slabs
Mots-clés en anglais
Experimental analysis
Hollow core slabs
Slim floor systems
Steel-concrete composite beams
Stud bolt
Resumé en anglais
On the world market, there is a visible tendency to turn buildings construction more industrialized and rationalized in order to reduce waste, accelerate the construction speed and ensure higher quality to them. The adoption of structural elements with a degree of industrialization can bring benefits regarding costs, labor, construction time and environmental impact. In this context, steel and concrete composite structures satisfy this need, since steel and concrete elements can be prefabricated, with only lifting and mounting steps to be performed on site, reducing use of formwork and shoring. A type of slim floor system consists in precast concrete hollow core slabs supported on the lower flange of steel beams. The major advantage of this solution, compared to conventional composite beam, is reducing the overall height of the floor. Therefore, this study aims to analyze the behavior of slim floor with prestressed concrete hollow core slabs through push-out and bending tests. In the proposed solution, the transfer of forces between steel beam and hollow core slabs was made by stud bolts and cast on site concrete. The obtained results proved to be promising in terms of slim floor behavior, significantly increasing the system stiffness regarding the isolated steel beam. In addition, a numerical modeling of the studied slim floor system was developed, using finite element based software DIANA®, in which the numerical model adequately represented the behavior of the composite beam, allowing parametric analysis.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2016-04-11
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.