Título em português
Reabilitação de paredes de alvenaria pela aplicação de revestimentos resistentes de argamassa armada.
Palavras-chave em português
alvenaria
argamassa armada
reabilitação
reforço
Resumo em português
O presente trabalho apresenta os resultados obtidos na pesquisa sobre o uso de revestimentos resistentes de argamassas de cimento e areia na reabilitação de paredes de alvenaria, quando solicitadas à compressão axial, compressão diagonal e flexão de painéis. Os ensaios foram baseados nas normas NBR 8949, ASTM 519 e NBR 14322 respectivamente. O objetivo dos ensaios realizados foi observar o comportamento estrutural de paredes de blocos de concreto revestidas com diversos tipos de argamassa de cimento e areia, os quais resultaram de combinações de argamassa de resistência baixa ou mais elevada, telas de aço soldadas, fibras de aço, fibras de polipropileno e conectores de cisalhamento. Os modelos dos ensaios de compressão axial tinham dimensões de 39 x 81 cm e foram confeccionados em gabaritos de aço para uma maior precisão durante o assentamento. Para os ensaios de compressão diagonal foram idealizados gabaritos de madeira para confecção e transporte dos modelos cujas dimensões eram de 80 x 80 cm. Nos ensaios de flexão as paredes (80 x 1,60) foram ensaiadas com a face maior na posição horizontal com duas situações de carregamento. Depois de terminados estes ensaios e analisados os resultados foi realizada também uma série de ensaios sobre painéis de alvenaria, submetidos a forças distribuídas numa região pequena do topo da parede e ensaiados em três situações diferentes: paredes íntegras, reabilitadas e reforçadas. A decisão de ensaiar painéis com aberturas se deu pela intenção de criar situações de desvio de tensões no plano da parede, provocando esforços de compressão, tração e cisalhamento. Todos os ensaios foram realizados com uso de equipamento hidráulico servo-controlado INSTRON, controlando-se a velocidade de deslocamento, o que permitiu observar o comportamento das paredes após à sua resistência de pico. Pode-se dizer que a técnica em estudo apresenta diversos aspectos interessantes, que podem ser explorados tanto na reabilitação (reforço ou reparo) de estruturas de alvenaria, como na execução de estruturas novas com exigências especiais de desempenho.
Título em inglês
Rehabilitation of masonty walls by the application of resistant ferrocement overlays.
Palavras-chave em inglês
ferrocement
masonry
rehabilitation
strengthening
Resumo em inglês
This paper reports on the results of a study about the use of resistant overlays of cement and sands mortars in the rehabilitation of masonry walls subjected to axial and diagonal compression and flexure. The tests were carried out according to the NBR8949, ASTM 519 and NBR 14322 codes. The purpose of the tests was to observe the structural behavior of concrete block walls covered with several combinations of materials: plain mortar with two different strengths, welded steel mesh, steel fibers, polypropylene fibers and shear connectors. The dimensions of the specimens subjected to axial compression tests were 390 x 810 mm. They were built inside steel templates for a better precision during their construction. Wooden templates were set up for the diagonal compression tests to build and transport the 800 x 800 mm specimens. In the flexure tests, the walls (800 x 1600 mm) were tested with the larger side in the horizontal position, using two loading situations. After the conclusion of these tests and an analysis of the results, a series of tests was carried out on masonry panels subjected to loads distributed over a small area at the top of the wall. Three different situations were tested, i.e., undamaged walls, rehabilitated walls and reinforced walls. The decision to test panels with openings was based on the idea of creating situations to deviate the stresses in the plane of the wall, thereby inducing compression, tension and shear. All the tests were performed using an universal servo-controlled INSTRON machine to control the displacement speed, allowing the observation of the behavior of the walls after their peak resistance. Based on this study, it can be stated that this technique offers several interesting aspects that may be applied both in the rehabilitation (strengthening or repair) of masonry structures and in the construction of new structures with special performance requirements.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Parte01.pdf (1.79 Mbytes)
Parte02.pdf (919.08 Kbytes)
Parte03.pdf (774.10 Kbytes)
Parte04.pdf (1.90 Mbytes)
Parte05.pdf (653.93 Kbytes)
Data de Publicação
2001-12-17
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.