Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.18.2009.tde-04082009-145407
Document
Auteur
Nom complet
Luciane Marcela Filizola de Oliveira
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2009
Directeur
Jury
Corrêa, Márcio Roberto Silva (Président)
Ramalho, Marcio Antonio
Silva, Roberto Marcio da
Titre en portugais
Cisalhamento nas interfaces verticais de paredes de edifícios de alvenaria estrutural
Mots-clés en portugais
Ações horizontais
Alvenaria estrutural
Carregamento vertical
Cisalhamento
Interfaces verticais
Resumé en portugais
Este trabalho apresenta a avaliação das tensões de cisalhamento nas interfaces verticais de paredes de alvenaria interconectadas em casos onde atuam simultaneamente carregamentos verticais e ações horizontais. Os valores obtidos para as máximas tensões de cisalhamento são comparados com as resistências estabelecidas na norma brasileira em vigor, NBR 10837 (ABNT, 1989), e no texto base para sua revisão. Os valores das referidas normas também são confrontados com valores experimentais, avaliando-se criticamente a aplicação dos limites normativos na prática de projetos de edifícios existentes. Adicionalmente, são avaliadas duas formas distintas de modelagem de edifícios de alvenaria estrutural, quando submetidos às ações horizontais. A primeira consiste em uma abordagem simplificada e bastante usual entre projetistas, a associação plana de paredes isoladas. Sua aferição é importante para fornecer ao projetista uma ferramenta que lhe permita obter resultados de maneira rápida e confiável. A segunda forma de modelagem é uma análise de pórtico tridimensional que permite uma análise mais completa das paredes de contraventamento, incluindo os efeitos das deformações por cisalhamento. Com o intuito de avaliar as diferenças observadas entre os dois modelos, foram empregados testes estatísticos, que permitem analisar se eles são estatisticamente iguais a um nível de significância de 5%. Para aquisição dos dados para as análises são feitos estudos de casos com quatro edifícios residenciais usuais, com diferentes arranjos arquitetônicos, variando-se o número de pavimentos em quatro, oito, doze e dezesseis, de modo a se obter maior representatividade dos resultados. Com os resultados obtidos nas avaliações, concluiu-se que os valores adotados como limites de resistência pelo texto base da revisão da NBR 10837 (ABNT, 1989) parecem ser rigorosos para realidade brasileira. Com relação à comparação dos modelos estudados, os testes estatísticos direcionam a uma conclusão importante, que é a de não haver diferença entre eles, para um nível de 5% de significância.
Titre en anglais
Shear stress on vertical interfaces of structural masonry walls
Mots-clés en anglais
Horizontal forces
Shear stress
Structural masonry
Vertical interfaces
Vertical loads
Resumé en anglais
This work presents the evaluation of the shear stress at the vertical interfaces of interconnected masonry walls simultaneously subjected to vertical and horizontal loads. The obtained maximum shear stress values are compared to the shear strengths prescribed by the current Brazilian code, NBR 10837 (ABNT, 1989), and by its review base text. The prescribed values are also confronted with experimental values, critically evaluating the application of the regulatory limits in the practical design of existing buildings. Additionally, two different ways of modeling the structural masonry buildings when submitted by horizontal actions are evaluated. The first one is a simple approach, largely used by designers, that consists in the two dimensional association of isolated walls. Its evaluation is important to provide the designer with a quick and reliable analytical tool. The second way of modeling is a three dimensional frame analysis, which allows a more complete simulation of the shear walls, including the shear strain effects. In order to evaluate the differences between the two models, statistical tests were employed for examining whether they are statistically equal at a significance level of 5%. Case studies were performed taking into account four residential buildings with different architectural arrangements. The number of floors was also varied considering four, eight, twelve and sixteen, in order to obtain more meaningful results. The developed analysis showed that the strength limits prescribed by the review base text of the NBR 10837 (ABNT, 1989) seem to be very much strict according to the Brazilian common practice. Regarding the comparison of the studied analytical models, the statistical tests showed that there is no difference between them at a significance level of 5%.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2009-08-07
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.