• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.18.2009.tde-04082009-145407
Documento
Autor
Nombre completo
Luciane Marcela Filizola de Oliveira
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2009
Director
Tribunal
Corrêa, Márcio Roberto Silva (Presidente)
Ramalho, Marcio Antonio
Silva, Roberto Marcio da
Título en portugués
Cisalhamento nas interfaces verticais de paredes de edifícios de alvenaria estrutural
Palabras clave en portugués
Ações horizontais
Alvenaria estrutural
Carregamento vertical
Cisalhamento
Interfaces verticais
Resumen en portugués
Este trabalho apresenta a avaliação das tensões de cisalhamento nas interfaces verticais de paredes de alvenaria interconectadas em casos onde atuam simultaneamente carregamentos verticais e ações horizontais. Os valores obtidos para as máximas tensões de cisalhamento são comparados com as resistências estabelecidas na norma brasileira em vigor, NBR 10837 (ABNT, 1989), e no texto base para sua revisão. Os valores das referidas normas também são confrontados com valores experimentais, avaliando-se criticamente a aplicação dos limites normativos na prática de projetos de edifícios existentes. Adicionalmente, são avaliadas duas formas distintas de modelagem de edifícios de alvenaria estrutural, quando submetidos às ações horizontais. A primeira consiste em uma abordagem simplificada e bastante usual entre projetistas, a associação plana de paredes isoladas. Sua aferição é importante para fornecer ao projetista uma ferramenta que lhe permita obter resultados de maneira rápida e confiável. A segunda forma de modelagem é uma análise de pórtico tridimensional que permite uma análise mais completa das paredes de contraventamento, incluindo os efeitos das deformações por cisalhamento. Com o intuito de avaliar as diferenças observadas entre os dois modelos, foram empregados testes estatísticos, que permitem analisar se eles são estatisticamente iguais a um nível de significância de 5%. Para aquisição dos dados para as análises são feitos estudos de casos com quatro edifícios residenciais usuais, com diferentes arranjos arquitetônicos, variando-se o número de pavimentos em quatro, oito, doze e dezesseis, de modo a se obter maior representatividade dos resultados. Com os resultados obtidos nas avaliações, concluiu-se que os valores adotados como limites de resistência pelo texto base da revisão da NBR 10837 (ABNT, 1989) parecem ser rigorosos para realidade brasileira. Com relação à comparação dos modelos estudados, os testes estatísticos direcionam a uma conclusão importante, que é a de não haver diferença entre eles, para um nível de 5% de significância.
Título en inglés
Shear stress on vertical interfaces of structural masonry walls
Palabras clave en inglés
Horizontal forces
Shear stress
Structural masonry
Vertical interfaces
Vertical loads
Resumen en inglés
This work presents the evaluation of the shear stress at the vertical interfaces of interconnected masonry walls simultaneously subjected to vertical and horizontal loads. The obtained maximum shear stress values are compared to the shear strengths prescribed by the current Brazilian code, NBR 10837 (ABNT, 1989), and by its review base text. The prescribed values are also confronted with experimental values, critically evaluating the application of the regulatory limits in the practical design of existing buildings. Additionally, two different ways of modeling the structural masonry buildings when submitted by horizontal actions are evaluated. The first one is a simple approach, largely used by designers, that consists in the two dimensional association of isolated walls. Its evaluation is important to provide the designer with a quick and reliable analytical tool. The second way of modeling is a three dimensional frame analysis, which allows a more complete simulation of the shear walls, including the shear strain effects. In order to evaluate the differences between the two models, statistical tests were employed for examining whether they are statistically equal at a significance level of 5%. Case studies were performed taking into account four residential buildings with different architectural arrangements. The number of floors was also varied considering four, eight, twelve and sixteen, in order to obtain more meaningful results. The developed analysis showed that the strength limits prescribed by the review base text of the NBR 10837 (ABNT, 1989) seem to be very much strict according to the Brazilian common practice. Regarding the comparison of the studied analytical models, the statistical tests showed that there is no difference between them at a significance level of 5%.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2009-08-07
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.