• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.18.2001.tde-28102015-102007
Document
Auteur
Nom complet
Mario Oleskovicz
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2001
Directeur
Jury
Coury, Denis Vinicius (Président)
Carvalho, André Carlos Ponce de Leon Ferreira de
Costa, Geraldo Roberto Martins da
Samesima, Milton Itsuo
Senger, Eduardo César
Titre en portugais
Aplicação de redes neurais artificiais na proteção de distância
Mots-clés en portugais
Classificação
Detecção
Localização de falta
Proteção de distância
Redes neurais artificiais
Sistemas de potência
Resumé en portugais
O presente trabalho visa apresentar um modelo alternativo e completo de proteção para linhas de transmissão utilizando-se de Redes Neurais Artificiais (RNAs). Pela aplicação, busca-se um modelo que venha a realizar a detecção do defeito, a classificação quanto ao tipo de falta ocorrida e a localização da mesma no que diz respeito à verificação das zonas de proteção em um menor tempo se comparado com as propostas convencionais. As grandezas analisadas referem-se a valores amostrados de tensões e correntes do sistema elétrico, cujos valores foram obtidos através de simulações computacionais utilizando o software Alternative Transientes Program (ATP). O desenvolvimento do trabalho está dividido em módulos, que dizem respeito à implementação das arquiteturas para a detecção, classificação e a localização da falta. Ressalta-se que o objetivo de treinar os módulos foi o de se obter arquiteturas de RNAs fixas (software NeuralWorks), as quais representam todo o conhecimento armazenado do sistema de proteção. Com estas arquiteturas fixas, através de um algoritmo computacional apropriado e implementado na linguagem de programação "C", pode-se então obter as respostas sobre todas as prováveis condições de operação do sistema de transmissão. Os resultados alcançados pela aplicação deste modelo alternativo de proteção ilustram que o desempenho global das arquiteturas de RNAs é altamente satisfatório e condizente para uma possível aplicação prática. Deve ser enfatizado que o esquema proposto se mostra altamente preciso, com alta velocidade de atuação, apresentando características bastante desejáveis para um sistema de proteção moderno. Deve ser mencionado que esta pesquisa foi desenvolvida em cooperação com o Departamento de Engenharia Elétrica e Eletrônica da Universidade de Bath/Inglaterra.
Titre en anglais
Artificial neural networks applied to distance protection
Mots-clés en anglais
Artificial neural networks
Classification and fault location
Detection
Distance protection
Power systems
Resumé en anglais
This work presents an alternative Artificial Neural Network (ANN) approach to simulate a complete scheme for a transmission line protection. From this application, we intend to obtain a complete model to detect the fault, to classify the fault type occurred and to locate it on the protection zones as quickly as possible when compared to conventional approaches. The voltage and current sampled values from the electric power system are analyzed and they are generated by computational simulation using the Alternative Transients Program (ATP) software. In order to perform the simulation, the study was subdivided into different neural network modules for fault detection, fault classification as well as fault location. It should be pointed out that the modules training objective was to obtain the appropriate fixed ANNs architectures (software NeuralWorks), which represent all stored knowledge from the protection system operation. With these fixed architectures, by an appropriate computational algorithm implemented in a C code language, all expected correct responses described above for different operation conditions can be obtained. The results obtained by application of this alternative protection approach, show that the global performance of the ANNs architecture was highly satisfactory and suitable to a practical application. It should be emphasized that the scheme proposed is highly precise with high speed of response, showing desirable characteristics to a modern protection system. It should be mentioned that this research was developed in cooperation with the Department of Electronic and Electrical Engineering - University of Bath/England.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2015-10-28
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.