• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.18.2007.tde-27082007-213453
Document
Author
Full name
Mauricio Cunha Escarpinati
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2007
Supervisor
Committee
Schiabel, Homero (President)
Mascarenhas, Yvone Maria
Moraes, José Carlos Teixeira de Barros
Netto, Thomaz Ghilardi
Traina, Agma Juci Machado
Title in Portuguese
Desenvolvimento de um sistema computacional para utilização em procedimentos de controle de qualidade em equipamentos mamográficos
Keywords in Portuguese
Controle de qualidade em imagens médicas
Digitalizadores
Filtro de Wiener
Mamografia
Processamento digital de imagens
Abstract in Portuguese
O presente trabalho consiste na elaboração de uma metodologia envolvendo técnicas computacionais para proporcionar informações provenientes de avaliação de qualidade de equipamentos mamográficos. A investigação conduzida levou em conta, além da necessária determinação de parâmetros operacionais - como tensão de pico (kVp), corrente de tubo, ponto focal, dose, tempo de exposição, camada semi-redutora -, a influência das características do digitalizador usado no processo de digitalização das imagens a ser avaliadas pelo esquema computacional, seja esse um sistema de aquisição digital direta ou indireta. Dessa forma, foi elaborado um protocolo de pré-processamento da imagem para compensar os efeitos do digitalizador antes da avaliação dos parâmetros de qualidade através dela. Simultaneamente ao desenvolvimento dos softwares necessários ao esquema, foi projetado e desenvolvido um simulador radiográfico para servir como instrumento para obtenção tanto das imagens a ser processadas pelo modelo computacional, como dos dados referentes aos parâmetros operacionais. O sistema foi desenvolvido tomando um mamógrafo calibrado e um instrumento de precisão como referências e testado em outros equipamentos mamográficos em operação em clínicas e hospitais. Os resultados foram consistentes com as análises comparativas utilizando as referências, o que podem fazer do sistema uma ferramenta útil na avaliação de qualidade em mamografia.
Title in English
Development of a computational system for quality control procedures on mammographic equipment
Keywords in English
Digital image processing
Digitizers
Mammography
Quality control on medical images
Wiener filter
Abstract in English
The present work consists on developing a computational methodology to provide information regarding to mammographic equipment quality evaluation. This investigation have taken into account, beyond the required operational parameters, such as kVp, electrical current, focal point, dose, exposition time, half-value layer, the influence of the film digitizer utilized for digitization process on the images to be evaluated by the computational scheme, either this a system of direct or indirect digital acquisition. Like so, it was elaborated an image pre-processing protocol to compensate the digitization effect on digital image, before the evaluation of quality control parameters through itself. Simultaneously to the development of the necessary software to the system, a radiographic phantom was developed to be used for achievement of either the images to be processed by the computational model, as operational parameters data. The system was developed taking calibrated mammographic equipment and a precise measurement instrument as references, besides, it was tested in other mammographic equipment in operation on clinics and hospitals. Results had shown consistent with the comparative analyses using those references, which can turn this system a useful tool for evaluation of mammography quality.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
TDMauricio.pdf (8.28 Mbytes)
Publishing Date
2007-09-04
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.