• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.18.2007.tde-26032008-153951
Document
Author
Full name
Paula Simone Saia
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2007
Supervisor
Committee
Ventura, Liliane (President)
Rodrigues, Evandro Luis Linhari
Sousa, Sidney Julio de Faria e
Title in Portuguese
Sistema ceratométrico de apoio a suturas na córnea
Keywords in Portuguese
Ceratometria intra-cirúrgica
Córnea
Sutura corneana
Abstract in Portuguese
Um sistema para auxílio à cirurgias oftálmicas foi desenvolvido com o objetivo de se minimizar o astigmatismo induzido devido ao formato irregular da córnea pelo ato de sutura. O sistema projeta 48 pontos de luz no filme lacrimal da córnea, provenientes de LEDs, dispostos num diâmetro precisamente circular. O deslocamento, a dimensão e a deformação da imagem refletida destes pontos luminosos são analisados proporcionando a ceratometria e a circularidade da sutura. O intervalo de medidas do sistema é de 32D - 55D (astigmatismos até 23D podem ser medidos) e um sistema para calibração do sistema foi projetado para manter o sistema calibrado. Esferas de aço de precisão foram submetidas ao sistema e uma correlação de 99% entre as medidas obtidas e os valores dos fabricantes foi obtida. O sistema foi testado em 13 voluntários para avaliação de sua aplicabilidade clínica e comparado a um ceratômetro comercial Topcon OM-4. Os fatores de correlação entre o sistema desenvolvido e o Topcon OM-4, para o astigmatismo, foi de 'R POT.2' = 0,92, e em relação ao eixo, o fator é 'R POT.2' = 0,99. O sistema indica que o cirurgião deve obter uma circularidade '> OU =' 98% para que astigmatismos acima de 3D não sejam induzidos na sutura.
Title in English
Keratomery system of the support to corneal sutures
Keywords in English
Cornea
Corneal suture
Surgical keratomery
Abstract in English
A system for ophthalmic surgery support has been developed in order to minimize the residual astigmatism due to the induced irregular shape of the cornea by corneal suture. The system projects 48 light spots, from LEDs, displayed in a precise circle at the lachrymal film of the examined cornea. The displacement, the size and deformation of the reflected image of these light spots are analyzed providing the keratometry and the circularity of the suture. Measurements in the range of 32D - 55D (up to 23D of astigmatism are possible to be obtained) and a self-calibration system has been designed in order to keep the system calibrated. Steel precision spheres have been submitted to the system and the results show 99% of correlation with the fabricant's nominal values. The system has been tested in 13 persons in order to evaluate its clinical applicability and has been compared to a commercial keratometer Topcon OM-4. The correlation factors are 0,92 for the astigmatism and 0.99 for the associated axis. The system indicates that the surgeon should achieve circularity '> OR =' 98% in order to do not induce astigmatisms over 3D.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Paula.pdf (4.58 Mbytes)
Publishing Date
2008-04-11
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.