• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.18.2017.tde-16112017-122329
Document
Auteur
Nom complet
Luis Carlos Caraschi
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 1999
Directeur
Jury
Slaets, Annie France Frère (Président)
Marques, Márcio Alexandre
Silva, Orivaldo Lopes da
Titre en portugais
Sistema de subtração digital de imagens para aplicações em angiografia
Mots-clés en portugais
Angiografia
Subtração digital
Resumé en portugais
No intuito de transformar sistemas de angiografia convencionais em sistemas de subtração digital com angiografia foram implementados três métodos de subtração digital: subtração digital por complemento de um, subtração por comparação 1 e subtração digital por comparação 2 e dois métodos de processamento: "threshold" e equalização para aplicação em sistemas angiográficos (DSA). O estudo destes métodos foi realizado com a simulação em sistemas gráficos a partir do qual foram avaliados o realce das pequenas estruturas vasculares, a influência do ruído e a velocidade de operação na subtração das imagens. Os algoritmos desenvolvidos em linguagem Pascal, utilizando Borland Delphi 2.0 (32 bits) foram testados com imagens obtidas no Hospital das Clínicas de Ribeirão Preto e os resultados foram comparados por análise visual.
Titre en anglais
not available
Mots-clés en anglais
Angiography
Digital subtraction
Resumé en anglais
In the intention of transforming systems of conventional angiography in systems of digital subtraction with angiography three methods of digital subtraction were implemented, digital subtraction for complement of a, subtraction for comparison 1 and digital subtraction for comparison 2 two processing methods: threshold and equalize for application in systems angiographycs (DSA). The study of these methods was accomplished with the simulation in graphic systems statting from which were appraised it enhances it of the small vascular structures, the influence of the noise and the operation speed in the subtraction of the images. The algorithms developed in linguage Pascal, using Borland Delphi 2.0 (32 bits) they were tested with images obtained in the Hospital of the Clinics in Ribeirão Preto and the results were compared by visual analysis.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2017-11-16
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.