  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.18.2008.tde-15102008-141521
Documento
Autor
Nombre completo
Clayton Eduardo dos Santos
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2008
Director
Tribunal
Slaets, Annie France Frère (Presidente)
Gonzaga, Adilson
Marques, Paulo Mazzoncini de Azevedo
Muhlen, Sergio Santos
Traina, Agma Juci Machado
Título en portugués
Modelagem computacional de estruturas anatômicas em 3D e simulação de suas imagens radiográficas
Palabras clave en portugués
Estruturas anatômicas
Fantoma computacional
Modelagem computacional
Simulação radiográfica
Resumen en portugués
Os métodos de controle de qualidade tradicionais aplicados ao radiodiagnóstico, é a melhor maneira de garantir a boa qualidade das imagens produzidas. No entanto, a investigação de particularidades oriundas do processo de formação de imagens radiológicas requer ferramentas computacionais complementares, em função do número de variáveis envolvidas. Entretanto, os fantomas computacionais baseados em voxels não conseguem representar as variações morfométricas necessárias para a simulação de exames cujo diagnóstico é baseado em imagem. Neste trabalho foi desenvolvido um novo tipo de fantoma computacional, baseado em modelagem 3D, que possui as vantagens apresentadas pelos fantomas computacionais tradicionais sem os problemas encontados nestes. A ferramenta de modelagem utilizada, o Blender, é disponibilizada gratuitamente na internet. A técnica utilizada foi a box modeling, que consiste na deformação de uma primitiva básica, nesse caso um cubo, até que apresente a forma da estrutura que se deseja modelar. Para tanto, foram utilizadas como referencia, imagens obtidas de atlas de anatomia e fotografias de um esqueleto fornecido pela Universidade de Mogi das Cruzes. Foram modelados o sistema ósseo, os órgãos internos e a anatomia externa do corpo humano. A metodologia empregada permitiu a alteração de parâmetros do modelo dentro da ferramenta da modelagem. Essa possibilidade foi mostrada através da variação, dos formatos do intestino e do aumento da quantidade de tecido adiposo da malha referente a pele. A simulação das imagens radiológicas foi realizada a partir de coeficientes de atenuação de massa de materiais, ossos e tecidos e de modelos com diversas características físicas. Essa versatilidade permite prever a influência que as diferenças morfométricas entre os indivíduos provocam nas imagens, propriciando dessa forma, uma ferramenta relevante complementar aos métodos de controle de qualidade tradicionais.
Título en inglés
Computational 3D modelling of anatomic structures and simulation of its radiography images
Palabras clave en inglés
Anatomic structures
Computational modelling
Computational phantom
Radiography simulation
Resumen en inglés
The conventional methods of quality control applied to radio diagnosis are the best way to have assured good quality of the produced images. Due the amount of variables to consider, the study of particular issues of the process of formation of radiological images requires complementary computational tools. However, the computational voxel based phantoms are not suitable to represent the morphometrical variations, intended for test simulations with image based diagnosis. This work developed a new type of computational phantom, based on 3D modelling. It has the same advantages of the conventional ones, without some of their restrictions. The modeling tool employed, Blender, is available on internet for free download. The project uses the technique called box modeling, which consists in the deformation of a primitive form (a cube, in this case) until it presents a similar form to that it is wanted to model. In order to achieve it, some images, obtained from anatomy atlas and a skeleton pictures obtained from University of Mogi das Cruzes, were used as reference. Were built models from skeletal system, internal organs and external human body anatomy. The applied methodology allowed model´s parameter settings on the modelling tool. This option was presented by means of intestine format variation and increase of adipose tissue on the mesh that represents skin. The simulation of radiological images was done by means of x-ray mass attenuation coefficients, bones and tissues and models with diferent physical characteristics. This flexibility allows the analysis and forecasting of the influences that morphometrical differences of individual implies on images, revealing an important tool that complements the conventional quality control tools.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Clayton.pdf (7.66 Mbytes)
Fecha de Publicación
2008-10-21
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.