Tese de Doutorado
DOI
https://doi.org/10.11606/T.18.2017.tde-15052017-155328
Documento
Autor
Nome completo
Marcelo Zanchetta do Nascimento
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Carlos, 2005
Orientador
Banca examinadora
Slaets, Annie France Frère (Presidente)
Gutierrez, Marco Antonio
Marques, Paulo Mazzoncini de Azevedo
Mühlen, Sérgio Santos
Rodrigues, Evandro Luis Linhari
Título em português
Método computacional automático para correção do efeito "heel" nas imagens radiográficas
Palavras-chave em português
Efeito "heel"
Imagem radiográfica
Não uniformidade do campo
Pré-processamento
Processamento de imagens
Raios X
Resumo em português
O diagnóstico radiográfico é baseado na análise das diferenças das densidades ópticas (DO) do filme, que deveriam ser provocadas apenas pelas estruturas anatômicas do paciente. Entretanto, a intensidade do feixe de raios X não é uniforme devido a um efeito intrínseco do equipamento de aquisição de imagem, conhecido como efeito "heel". Estas variações prejudicam tanto a análise visual quanto o processamento computacional (CAD) das pequenas estruturas anatômicas. O presente trabalho apresenta um método computacional que corrige as diferenças de densidades ópticas produzidas na radiografia pelo efeito "heel". Esse método foi implementado utilizando ambiente de programação Delphi, rotinas em C e Matlab. O método simula a distribuição da intensidade ao longo do campo de radiação, determinando o caminho de absorção que os fótons sofrem dentro do alvo utilizando os modelos de Kramers e Fritz Livingston. Calcula a correlação espacial entre a radiografia e a imagem simulada, localizando o eixo anodo/catodo e o centro do campo nas duas imagens, empregando a função de correlação estatística de Pratt e a função de mapeamento de Zitová e Flusser. Calcula tanto os percentuais de radiação recebidos para cada ponto simulado em relação à radiação ao centro do campo, quanto os percentuais dos níveis de cinza de cada pixel da radiografia e corrige esse valor em função do correspondente na simulação. O algoritmo desenvolvido permitiu determinar a posição do centro do campo de radiação com precisão em torno de 1% e eliminou aproximadamente 90% do efeito "heel" na radiografia permitindo que os objetos apresentassem densidades ópticas coerentes com suas absorções específicas. Um estudo preliminar mostrou que esse método poderá ser utilizado como pré-processamento dos sistemas CAD.
Título em inglês
An automatic computational method for correction of the heel effect in radiographic images
Palavras-chave em inglês
Computational simulation
Heel effect
Image processing
Non uniformity field
Preprocessing
Radiographic image
X-ray
Resumo em inglês
The radiographic diagnosis is based on the analysis of the film optical density differences that should be created only by the patient anatomical structures. However, the intensity of the x-ray beam is not uniform due to an intrinsic effect to the image acquisition equipment, known as heel effect. These variations damage the visual analysis as well the (CAD) computer processing of the small anatomical structures. The current work presents a computer method that corrects the optical densities differences generated in the radiography by heel effect. This method was implemented using Delphi Programming Environment, routines in C and Matlab. The method simulates the intensity distribution along the radiation field, determining the absorption path that photons suffer inside the target using the models of Kramers and Fritz and Livingston. It calculates the space correlation between the radiography and the simulated image, determining the anode/cathode axis and the field center in the two images, using the statistics function of Pratt and the mapping function of Zitová and Flusser. It calculates as much the received radiation, percentage for each simulated point in relation the field center radiation, as the gray scales percentage of each radiography pixel and corrects their values as function of the correspondent in the simulation. The developed algorithm has allowed to determine the center position of the radiation field with about 1% precision and approximately eliminated 90%of the heel effect in the radiography, allowing the objects to present optical densities coherent with their specific absorptions. A preliminary study has showen that this method can be used as preprocessing of CAD systems.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2017-05-15
 