Tesis Doctoral
DOI
https://doi.org/10.11606/T.18.2017.tde-15052017-155328
Documento
Autor
Nombre completo
Marcelo Zanchetta do Nascimento
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2005
Director
Tribunal
Slaets, Annie France Frère (Presidente)
Gutierrez, Marco Antonio
Marques, Paulo Mazzoncini de Azevedo
Mühlen, Sérgio Santos
Rodrigues, Evandro Luis Linhari
Título en portugués
Método computacional automático para correção do efeito "heel" nas imagens radiográficas
Palabras clave en portugués
Efeito "heel"
Imagem radiográfica
Não uniformidade do campo
Pré-processamento
Processamento de imagens
Raios X
Resumen en portugués
O diagnóstico radiográfico é baseado na análise das diferenças das densidades ópticas (DO) do filme, que deveriam ser provocadas apenas pelas estruturas anatômicas do paciente. Entretanto, a intensidade do feixe de raios X não é uniforme devido a um efeito intrínseco do equipamento de aquisição de imagem, conhecido como efeito "heel". Estas variações prejudicam tanto a análise visual quanto o processamento computacional (CAD) das pequenas estruturas anatômicas. O presente trabalho apresenta um método computacional que corrige as diferenças de densidades ópticas produzidas na radiografia pelo efeito "heel". Esse método foi implementado utilizando ambiente de programação Delphi, rotinas em C e Matlab. O método simula a distribuição da intensidade ao longo do campo de radiação, determinando o caminho de absorção que os fótons sofrem dentro do alvo utilizando os modelos de Kramers e Fritz Livingston. Calcula a correlação espacial entre a radiografia e a imagem simulada, localizando o eixo anodo/catodo e o centro do campo nas duas imagens, empregando a função de correlação estatística de Pratt e a função de mapeamento de Zitová e Flusser. Calcula tanto os percentuais de radiação recebidos para cada ponto simulado em relação à radiação ao centro do campo, quanto os percentuais dos níveis de cinza de cada pixel da radiografia e corrige esse valor em função do correspondente na simulação. O algoritmo desenvolvido permitiu determinar a posição do centro do campo de radiação com precisão em torno de 1% e eliminou aproximadamente 90% do efeito "heel" na radiografia permitindo que os objetos apresentassem densidades ópticas coerentes com suas absorções específicas. Um estudo preliminar mostrou que esse método poderá ser utilizado como pré-processamento dos sistemas CAD.
Título en inglés
An automatic computational method for correction of the heel effect in radiographic images
Palabras clave en inglés
Computational simulation
Heel effect
Image processing
Non uniformity field
Preprocessing
Radiographic image
X-ray
Resumen en inglés
The radiographic diagnosis is based on the analysis of the film optical density differences that should be created only by the patient anatomical structures. However, the intensity of the x-ray beam is not uniform due to an intrinsic effect to the image acquisition equipment, known as heel effect. These variations damage the visual analysis as well the (CAD) computer processing of the small anatomical structures. The current work presents a computer method that corrects the optical densities differences generated in the radiography by heel effect. This method was implemented using Delphi Programming Environment, routines in C and Matlab. The method simulates the intensity distribution along the radiation field, determining the absorption path that photons suffer inside the target using the models of Kramers and Fritz and Livingston. It calculates the space correlation between the radiography and the simulated image, determining the anode/cathode axis and the field center in the two images, using the statistics function of Pratt and the mapping function of Zitová and Flusser. It calculates as much the received radiation, percentage for each simulated point in relation the field center radiation, as the gray scales percentage of each radiography pixel and corrects their values as function of the correspondent in the simulation. The developed algorithm has allowed to determine the center position of the radiation field with about 1% precision and approximately eliminated 90%of the heel effect in the radiography, allowing the objects to present optical densities coherent with their specific absorptions. A preliminary study has showen that this method can be used as preprocessing of CAD systems.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2017-05-15
 