• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.18.2007.tde-03122007-164408
Documento
Autor
Nombre completo
Ana Cláudia Martinez
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2007
Director
Tribunal
Schiabel, Homero (Presidente)
Carneiro, Antonio Adilton Oliveira
Cliquet Junior, Alberto
Gonzaga, Adilson
Mascarenhas, Nelson Delfino D'Ávila
Título en portugués
Desenvolvimento de novas técnicas para redução de falso-positivo e definição automática de parâmetros em esquemas de diagnóstico auxiliado por computador em mamografia
Palabras clave en portugués
CAD
Detecção automática de nódulos e microcalcificações
Mamografia
Redução de falso-positivo
Seleção automática de regiões de interesse
Resumen en portugués
O presente trabalho consiste na investigação das características da imagem mamográfica digitalizada para definir automaticamente parâmetros de processamento em um esquema de diagnóstico auxiliado por computador (CAD) para mamografia, com o objetivo de se obter o melhor desempenho possível. Além disso, com base na aplicação dos resultados dessa primeira investigação, propõe-se também uma técnica de redução dos índices de falso-positivo em esquemas CAD visando à redução do número de biópsias desnecessárias. Para a definição automática dos parâmetros de processamento nas técnicas de detecção de microcalcificações e nódulos, foram extraídas algumas características das imagens, como desvio padrão, terceiro momento e o limiar de binarização. Utilizando o método de automatização proposto, observou-se um aumento de 20% no desempenho do esquema CAD (Az da curva ROC) em relação ao método não automatizado com parâmetro fixo. Para que fosse possível o processamento da imagem mamográfica inteira pelo esquema CAD e as técnicas desenvolvidas, foi desenvolvida também uma técnica para seleção automática de regiões de interesses, que recorta partes relevantes da mama para a segmentação. O índice de falsos positivos foi tratado por técnica específica desenvolvida com base na comparação das duas incidências típicas do exame mamográfico que, juntamente com a avaliação automática da imagem no pré-processamento para detecção de microcalcificações produziu uma redução significativa de 86% daquela taxa em relação ao procedimento de parâmetro fixo.
Título en inglés
Development of news technique for reduction of false-positive and automatic definition of parameters of mammograms for CAD schemes
Palabras clave en inglés
Automatic selection of regions of interests
CAD
Detection automatic of microcalcifications and nodules
Mammography
Reduction of false-positive
Resumen en inglés
This present work consists on the investigation of mammographic image characteristics for automatic determination of image processing parameters for a mammography computer aided diagnosis scheme (CAD) in order to get optimal performance. Additionally, using the results obtained on this first investigation, it was also developed a new technique for the reduction of false-positive rates on CAD projects, which can result on the reduction of the number of unnecessary biopsies. For the automatic definition of the image processing parameters for the techniques of detection of microcalcifications and nodules, some image characteristics had been extracted, as standard deviation, third momentum and the thresholding value. Using the proposed automatization method it was reported an increase of 20% in the CAD performance (evaluated determining the ROC curve) in comparison to the non-automatic method (fixed parameter). Besides, for CAD schemes it is necessary to process the entire mammographic image. Thus, it was also developed a technique for automatic selection of regions of interests in the mammogram, which extracts better regions from breast image for further segmentation. False-positives rates was treated by a specific technique based on the comparison of the two typical incidences of mammographic examination that together with the automatic parameter determination method for microcalcification detection produced a significant reduction of 86% of that rate in relation to the procedure that uses fixed parameter.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Ana.pdf (4.18 Mbytes)
Fecha de Publicación
2007-12-13
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.