• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.18.2002.tde-28072006-142637
Document
Author
Full name
Wilson Cartaxo Soares
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2002
Supervisor
Committee
Cintra, Jose Carlos Angelo (President)
Aoki, Nelson
Bezerra, Raimundo Leidimar
Title in Portuguese
Estacas de compactação para melhoria de solo
Keywords in Portuguese
diagrama de cravação
estaca de compactação
índice de resistência à penetração
prova de carga estática
Abstract in Portuguese
Este trabalho apresenta alguns parâmetros geotécnicos do solo arenoso na região litorânea de João Pessoa/PB, após a melhoria com estacas de compactação, instaladas pelo método denominado vibro-deslocamento. Esse procedimento é um método de melhoria de solos arenosos em que as estacas de areia e brita são introduzidas em solos de baixa resistência com o propósito de aumentar sua resistência e diminuir os recalques da fundação. Realizaram-se ensaios de cone, prova de carga em placa, sondagem SPT e anotação do diagrama de cravação das estacas, para se estudarem os efeitos da melhoria do solo arenoso por meio de estacas de compactação. São mostradas correlações entre o 'N IND.SPT', antes e após a compactação do solo, entre a resistência de ponta do cone e 'N IND.SPT', antes e após a compactação, bem como os resultados de provas de carga em placa, realizadas nos solos natural e compactado. Observou-se que a diminuição do espaçamento entre estacas aumenta a resistência do solo. Com base no 'N IND.SPT', é apresentada uma forma de previsão da capacidade de carga de fundações por sapata, instaladas em solo arenoso compactado com estacas de areia
Title in English
Compaction piles to soil improvement
Keywords in English
compaction piles
drive diagram
plate load test
standard penetration test
Abstract in English
This work presents some geotechnical parameters in sandy soil improved by compaction piles installed by vibro-displacement on the cost of the city of João Pessoa in Northeastern Brazil. Significant increases on bearing capacity can be achieved with this ground improvement technique allowing the use of shallow foundation, even in the case of high buildings. Forty eight sand piles with diameter of 0,30 m and 3,5 m long were installed on three different groups varying distance between the piles. Standard penetration tests, cone penetration tests and plate load tests were carried out before and after the installation of piles. The comparison between the tests allows quantify the benefit of soil improvement by compaction piles. Empirical relationships between 'N IND.SPT' before and after improvement, and relationships between qc and 'N IND.SPT' were established. These relations and results of plate load tests allowed an assessment of the influence of distance between the piles in the compacted soil. A prediction of bearing capacity of shallow foundations in sandy soil improved by sand piles, based on 'N IND.SPT' values is presented
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
dissertacao.pdf (2.38 Mbytes)
Publishing Date
2006-08-01
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.