• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.18.2005.tde-28042006-092801
Document
Auteur
Nom complet
Danilo Pacheco e Silva
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2005
Directeur
Jury
Esquivel, Edmundo Rogerio (Président)
Giacheti, Heraldo Luiz
Lollo, Jose Augusto de
Titre en portugais
Influência da contaminação por cloreto de cobre na resistência ao cisalhamento de solos utilizados em liners
Mots-clés en portugais
aterro sanitário
cloreto de cobre
contaminação
liner
resistência ao cisalhamento
Resumé en portugais
Avaliou-se, experimentalmente, o efeito da contaminação, por uma solução de cloreto de cobre, na resistência ao cisalhamento de solos a serem utilizados na construção de liners. Foi escolhido o cloreto de cobre como contaminante pelo fato de os íons cobre serem os mais comuns nos aterros sanitários industriais. Apresentam-se resultados de ensaios de percolação em colunas e ensaios triaxiais convencionais do tipo CU para solos provenientes das formações Serra Geral (argilosos), Botucatu (arenosos) e uma mistura dos mesmos na proporção de 20% de solo Serra Geral e 80% de solo Botucatu. A mistura apresentou condutividade hidráulica e resistência mais adequadas para utilização em liners do que cada um dos solos isolados. Da análise dos resultados dos ensaios triaxiais do tipo CU, constatou-se a maior influência da contaminação no comportamento do solo Serra Geral, como conseqüência da dupla camada elétrica. Para os três solos, observou-se que o efeito da contaminação foi mais pronunciado para menores tensões confinantes
Titre en anglais
Copper chloride contamination influence on the shear strength of soils used as liners
Mots-clés en anglais
contamination
copper chloride
liner
sanitary landfill
shear strength
Resumé en anglais
The contamination effects of copper chloride, on the shear strength of soils to be used as liners, were experimentally testes in laboratory. The copper chloride was chosen as the contaminant agent because it is the most common in found in industrial sanitary landfills. The results of percolation and conventional triaxial tests for soils from Serra Geral formation (clayed soils), Botucatu formation (sandy soils) and a mix in a convenient proportion with both soils are presented. The hydraulic condutivity and strength of the mixed soil indicated that it is more suitable to be used as liners than the original soils. From the comparison of triaxial test results, the effects of contamination were more significant in the soils from the Serra Geral formation as a consequence of the electrical double layer. For the three soils, the effects of contamination were more noticeable for smaller confining pressures
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
dissertacao.pdf (3.13 Mbytes)
Date de Publication
2006-04-28
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.