Avaliação da superfície deformada de geomembrana de PEAD sob camadas de proteção por meio do ensaio de compressão estática
Palabras clave en portugués
Compressão estática
Geomembrana
Puncionamento
Stress crack
Resumen en portugués
Nos sistemas de revestimento de fundo de aterros sanitários e pilhas de rejeito de mineração, é comum utilizar geotêxtil não-tecido para a proteção ao puncionamento da geomembrana por objetos pontiagudos como a brita. Neste trabalho, realiza-se um estudo experimental a fim de avaliar a superfície deformada de geomembrana de PEAD, com 2 mm de espessura, em camada de proteção sujeita a carregamentos de 600 kPa e 1800 kPa ao longo de 100 h, com o objetivo de simular danos mecânico de operação. Para a leitura da superfície deformada da geomembrana utilizou-se um lençol de chumbo localizado sob a geomembrana e as suas deformações foram estimadas a partir de uma máquina de leitura por coordenadas, com grid de 4 mm. Além deste, foi estimada a superfície deformada da geomembrana para o grid de 1 mm, com a aplicação do método de interpolação chamado de triangulação. Ainda foram utilizados extensômetros elétricos para estimar deformações pontuais na geomembrana. A fim de prevenir o puncionamento da geomembrana e limitar a sua deformação, utilizou-se como camada de proteção quatro geotêxteis não tecidos do tipo PP com massa por unidade de área variando entre 550 e 1300 g/m2, e uma camada de 10 cm de argila. Para a carga de 600 kPa, todas as camadas de proteção foram eficientes para evitar o puncionamento da geomembrana e limitar a sua deformação em 6%. Na carga de 1800 kPa, para proteção de geotêxtil, as configurações duplas tiveram melhor desempenho com valores de deformações menores que 6%, e a camada de 10 cm de argila foi ainda mais eficaz. Por fim, o trabalho mostrou que a superfície deformada decorrente do tipo de proteção adotado também é influenciada pelo grau de compactação do solo, o tipo de brita, a carga aplicada e as propriedades físicas do elemento de proteção.
Título en inglés
Evaluation of the deformed surface of PEAD geomembrane in protective layers by means of the static compression test
Palabras clave en inglés
Geomembrane
Puncture
Static compression
Stress crack
Resumen en inglés
In landfill backfill systems and mining tailings piles, it is common to use nonwoven geotextiles to protect geomembrane punctures by sharp objects such as gravel. In this work, an experimental study was carried out to evaluate the deformed HDPE geomembrane surface, with a thickness of 2 mm, under a protective layer subjected to loads of 600 kPa and 1800 kPa over 100 h, with the objective of Simulate mechanical damage of operation. To read the deformed surface of the geomembrane was used a sheet of lead located under the geomembrane and its deformations were estimated from a machine of reading by coordinates, with grid of 4 mm. Also, the deformed surface of the geomembrane was estimated for the grid of 1 mm, with the application of the interpolation method called triangulation. Electrical extensometers were also used to estimate point deformations in the geomembrane. In order to prevent the puncture of the geomembrane and to limit its deformation, four non-woven PP-type geotextiles with a mass per unit area ranging from 550 to 1300 g/m2 and a layer of 10 cm of clay. At the load of 600 kPa, all the layers of protection were efficient to avoid the puncture of the geomembrane and to limit its deformation in 6%. In the vertical load of 1800 kPa, for geotextile protection, the double configurations had better performance with deformation values lower than 6%, and the 10 cm layer of clay was even more effective. Finally, the work showed that the deformed surface resulting from the type of protection adopted is also influenced by the degree of soil compaction, the type of gravel, the applied load and the physical properties of the protection element.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2017-10-26
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.