• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.18.2000.tde-18102006-101542
Documento
Autor
Nome completo
Ana Paula Fontana Vianna
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Carlos, 2000
Orientador
Banca examinadora
Cintra, Jose Carlos Angelo (Presidente)
Aoki, Nelson
Chamecki, Paulo Roberto
Título em português
Análise de provas de carga estática em estacas pré-moldadas cravadas na cidade de Curitiba e região metropolitana
Palavras-chave em português
carga última
curva carga x recalque
prova de carga
Resumo em português
Nesta dissertação são analisadas 34 provas de carga estática realizadas em estacas pré-moldadas de concreto, cravadas em diferentes locais da cidade de Curitiba e região metropolitana, sendo a maioria delas na Formação Guabirotuba. Três métodos de previsão da capacidade foram analisados: Aoki – Velloso (1975), Décourt – Quaresma (1978) e Amaral (1982, 1999). Para cada método foram propostos fatores de correção global e/ou parcial que tornam o valor da capacidade de carga mais próximo do valor da carga última obtida pelo critério de Van der Veen (1953). Com base em quatro provas de carga conduzidas até a ruptura, estudou-se a aplicabilidade do método de Van der Veen (1953) e determinou-se um critério para avaliar a extrapolação da curva carga x recalque em ensaios encerrados sem atingir a ruptura. Finalmente fez-se uma análise dos recalques comparando-se os valores medidos com os calculados, para três níveis de carregamento, além da comparação das curvas carga x recalque ajustadas com as experimentais.
Título em inglês
Analysis of static loading tests in concrete drive pile carried out in Curitiba city and metropolitan area
Palavras-chave em inglês
load-settlement curve
static load test
ultimate load
Resumo em inglês
This thesis presents the analysis of 34 static loading tests in concrete drive pile, located at different places of the Curitiba city and metropolitan area, in Guabirotuba Formation. Three methods of the bearing capacity prediction were assessed: Aoki – Velloso (1975), Décourt – Quaresma (1978) and Amaral (1982, 1999). For each method is proposed global correction factors and/or partial that turned the bearing capacity value close to the ultimate load obtained for the Van der Veen criteria (1953). Based on four static loading test carried out to failure, the applicability of the Van der Veen criteria was assessed and was determined a rule to evaluate the extrapolation of the load - settlement curve in tests stopped before of the failure. Finally, it was made an analysis of the settlements, where it was compared the observed values and the predicted values, for three loading level, and also a comparison between the experimental load-settlement curve and the predicted load-settlement curve.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
dissertacao.pdf (2.75 Mbytes)
Data de Publicação
2006-10-30
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.