Titre en portugais
Barreiras de solos estabilizados com cal e cimento para proteção ambiental
Mots-clés en portugais
Condutividade hidráulica
Estabilização química
Planejamento fatorial
Resistência à compressão simples
Solo-cal
Solo-cimento
Resumé en portugais
Este trabalho apresenta a avaliação dos efeitos da estabilização química com cal e cimento na condutividade hidráulica e resistência à compressão de um solo arenoso proveniente da Formação Botucatu (Estado de São Paulo, Brasil), com o objetivo de obter um material menos permeável e mais resistente. O projeto e análise de experimentos foram realizados através de um planejamento fatorial 3², com duas variáveis independentes: teor de umidade e porcentagem de estabilizante, variando em três níveis cada. Foi utilizado cal hidratada CH-III, cimento Portland CP II-Z32 e água fornecida pela concessionária local. Os ensaios de condutividade hidráulica (K) foram executados em permeâmetros de carga constante. Foram realizados ensaios de resistência a compressão simples (RC) após 7 e 28 dias de cura. As amostras de solo estabilizado e natural foram compactadas na energia Proctor Normal. Na avaliação da estrutura das amostras de solo estabilizado verificou-se a alteração da matriz de poros promovida pela adição de cal e cimento. Após a obtenção dos resultados, análises estatísticas possibilitaram avaliar os efeitos das variáveis independentes sobre o K e RC. Pelo método de superfície de respostas foi possível demonstrar o comportamento das misturas e identificar a tendência de alteração das propriedades. As amostras de solo-cimento alcançaram reduções de condutividade hidráulica de até 9,5 x 10-7 m/s e o menor valor experimental de K foi de 1,4 x 10-8 m/s. Os ensaios de RC, com 28 dias de cura, apresentaram acréscimo de resistência de até 5,1 MPa e os resultados obtidos possuem uma variação, aproximadamente, entre 0,1 e 5,1 MPa. O procedimento adotado permitiu avaliar a influência dos fatores e determinar as misturas ótimas para cada estabilizante.
Titre en anglais
Soil barriers chemically stabilized with lime and cement to environmental protection
Mots-clés en anglais
Factorial design
Hydraulic conductivity
Soil stabilization
Soil-cement
Soil-lime
Unconfined compressive strength
Resumé en anglais
A laboratory study was conducted to evaluate the effects of lime and cement stabilization over the hydraulic conductivity and unconfined compressive strength of a sandy soil from Botucatu Formation (São Paulo State, Brazil) with the intend to generate a less permeable and more resistant material. The experiment was performed using the technique of factorial design 3², with the two independent variables: moisture content and stabilizer percentage, varying on three levels each. Hydraulic conductivity (K) was measured in constant-head permeameters. Unconfined compressive strength (CS) was measured after 7 and 28 days of curing. The samples of stabilized and natural soils were compacted with the normal Proctor energy. The evaluation of the stabilized soil structure verified a pore matrix modification promoted by lime and cement addition. With the results of the characterization, statistical analysis allowed to assess the effects of the variable factors on K and CS. The response surface method was used to demonstrate the hydraulic and compressive strength behavior of the stabilized soil. The soil-cement hydraulic conductivity achieved reductions up to 9.5 x 10-7 m/s and the lowest K experimental value was 1.4 x 10-8 m/s. The compressive strength, with 28 days of curing, presented an increase in CS up to 5.1 MPa and the obtained results showed a range between 0.1 and 5.1 MPa. The adopted experimental procedure allows the assessment of the variables influence and the determination of the optimal mixtures for each stabilizer.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
loch.pdf (9.56 Mbytes)
Date de Publication
2014-04-30
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.