• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.18.2013.tde-13032014-154440
Documento
Autor
Nombre completo
Felipe de Campos Loch
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2013
Director
Tribunal
Pejon, Osni José (Presidente)
Miguel, Miriam Gonçalves
Rodrigues, Valeria Guimarães Silvestre
Título en portugués
Barreiras de solos estabilizados com cal e cimento para proteção ambiental
Palabras clave en portugués
Condutividade hidráulica
Estabilização química
Planejamento fatorial
Resistência à compressão simples
Solo-cal
Solo-cimento
Resumen en portugués
Este trabalho apresenta a avaliação dos efeitos da estabilização química com cal e cimento na condutividade hidráulica e resistência à compressão de um solo arenoso proveniente da Formação Botucatu (Estado de São Paulo, Brasil), com o objetivo de obter um material menos permeável e mais resistente. O projeto e análise de experimentos foram realizados através de um planejamento fatorial 3², com duas variáveis independentes: teor de umidade e porcentagem de estabilizante, variando em três níveis cada. Foi utilizado cal hidratada CH-III, cimento Portland CP II-Z32 e água fornecida pela concessionária local. Os ensaios de condutividade hidráulica (K) foram executados em permeâmetros de carga constante. Foram realizados ensaios de resistência a compressão simples (RC) após 7 e 28 dias de cura. As amostras de solo estabilizado e natural foram compactadas na energia Proctor Normal. Na avaliação da estrutura das amostras de solo estabilizado verificou-se a alteração da matriz de poros promovida pela adição de cal e cimento. Após a obtenção dos resultados, análises estatísticas possibilitaram avaliar os efeitos das variáveis independentes sobre o K e RC. Pelo método de superfície de respostas foi possível demonstrar o comportamento das misturas e identificar a tendência de alteração das propriedades. As amostras de solo-cimento alcançaram reduções de condutividade hidráulica de até 9,5 x 10-7 m/s e o menor valor experimental de K foi de 1,4 x 10-8 m/s. Os ensaios de RC, com 28 dias de cura, apresentaram acréscimo de resistência de até 5,1 MPa e os resultados obtidos possuem uma variação, aproximadamente, entre 0,1 e 5,1 MPa. O procedimento adotado permitiu avaliar a influência dos fatores e determinar as misturas ótimas para cada estabilizante.
Título en inglés
Soil barriers chemically stabilized with lime and cement to environmental protection
Palabras clave en inglés
Factorial design
Hydraulic conductivity
Soil stabilization
Soil-cement
Soil-lime
Unconfined compressive strength
Resumen en inglés
A laboratory study was conducted to evaluate the effects of lime and cement stabilization over the hydraulic conductivity and unconfined compressive strength of a sandy soil from Botucatu Formation (São Paulo State, Brazil) with the intend to generate a less permeable and more resistant material. The experiment was performed using the technique of factorial design 3², with the two independent variables: moisture content and stabilizer percentage, varying on three levels each. Hydraulic conductivity (K) was measured in constant-head permeameters. Unconfined compressive strength (CS) was measured after 7 and 28 days of curing. The samples of stabilized and natural soils were compacted with the normal Proctor energy. The evaluation of the stabilized soil structure verified a pore matrix modification promoted by lime and cement addition. With the results of the characterization, statistical analysis allowed to assess the effects of the variable factors on K and CS. The response surface method was used to demonstrate the hydraulic and compressive strength behavior of the stabilized soil. The soil-cement hydraulic conductivity achieved reductions up to 9.5 x 10-7 m/s and the lowest K experimental value was 1.4 x 10-8 m/s. The compressive strength, with 28 days of curing, presented an increase in CS up to 5.1 MPa and the obtained results showed a range between 0.1 and 5.1 MPa. The adopted experimental procedure allows the assessment of the variables influence and the determination of the optimal mixtures for each stabilizer.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
loch.pdf (9.56 Mbytes)
Fecha de Publicación
2014-04-30
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.