Tesis Doctoral
DOI
https://doi.org/10.11606/T.18.2018.tde-10052018-104421
Documento
Autor
Nombre completo
Cornélio Zampier Teixeira
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 1997
Director
Tribunal
Albiero, José Henrique (Presidente)
Aoki, Nelson
Carvalho, David de
Cintra, José Carlos Angelo
Lobo, Ademar da Silva
Título en portugués
Capacidade de carga de sapatas, estacas de pequeno diâmetro e tubulões curtos em função do SPT: um estudo em solos residuais de Gnaisses para a região Sul de Minas
Palabras clave en portugués
Estaca-broca
Geologia residual
Parâmetros geotécnicos
Prova de carga rápida
Solos residuais de Gnaisse
Tubulões curtos instrumentados
Resumen en portugués
Esta Tese aborda, de modo original e pioneiro, importantes aspectos da Engenharia de Fundações do Sul de Minas: a) sistematização de conhecimentos sobre a Geologia regional; b) identificação e caracterização da prática de fundações; c) definição (com a formação de um banco de dados) dos perfis mais representativos do subsolo de suas principais cidades; d) estudo dos parâmetros físicos, químicos e geomecânicos de um solo típico; e) implantação de campo experimental de fundações da Universidade Federal de Lavras, com a realização de provas de carga. Grande ênfase foi dada aos itens (a), (c) e (e). Priorizou-se o estudo das fundações de baixa capacidade de carga, no estudo do comportamento carga-recalque de ensaios de placa, de provas de carga a compressão em estacas-broca isoladas e de tubulões curtos instrumentados. Destacam-se as análises sobre os efeitos de forma, profundidade, melhoramento do terreno de fundação e de inundação nas fundações rasas e da variação L/d na resistência lateral unitária das estacas, sendo valorizadas as fórmulas empíricas com base no SPT. São apresentadas fórmulas de previsão de carga, em função do SPT, para sapatas, estacas de pequeno diâmetro e tubulões curtos e um estudo de custos, onde se mostra que a opção indiscriminada por tubulões é inadequada para certas faixas de carga de trabalho. Adicionalmente, são feitas recomendações para intensificar o uso de sondagens tendo em vista a grande variabilidade das propriedades dos solos regionais e para aumentar os fatores de segurança nestas fórmulas onde houver possibilidade de ocorrência de colapso no solo.
Título en inglés
Bearing capacity and shaft resistance for shallow foundations, small diameters piles and short drilled piers, as function of SPT: a study for the residuals soils from gneis of the southern region of the Minas Gerais State at Brasil
Palabras clave en inglés
Drilled shaft piles
Geotechnical parameters
Instrumented short piers
QML load proofs
Regional geology
Residual soil from gneiss
Resumen en inglés
This work presents, at time, important aspects of Foundation Engineering at Southern Region of Minas Gerais State: a) systematization of the knowledge about regional geology; b) identification and characterization of practice in foundations; c) definition (though establishment of a data base) of most representative sub-soil profiles at main cities at the region; d) study of physical, chemical and geomechanical parameters of a typical soil; e) implementation of a experimental field for foundation studies at Federal University of Lavras, by execution of load tests. A large emphasis was given to items a, c and e. The study of foundations of low load capacity was prioritized when testing plates, isolated piles under compression and short drilled piers with sensors. Analysis such as form effects, depth, soil improvement and flooding on shallow foundations and variation of L/d on the lateral unity resistance by emphasizing the empiral equations based on SPT were all pointed out. Mathematical equations are presented for load estimation as function of SPT for small diameter piles and short drilled piers as well as a cost study where it can bem shown that the undistinguished alternative for piers is inadequate for some load values. In addition, due to soil spatial variability and safety factor increment on soils subject for colapse, recommendations on intensive use of SPT test are given.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2018-05-10
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.