• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.18.2011.tde-07122011-095718
Document
Auteur
Nom complet
Albano Sâlzon Maparagem
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2011
Directeur
Jury
Bueno, Benedito de Souza (Président)
Gaioto, Nélio
Lodi, Paulo César
Titre en portugais
Avaliação da interação solo-fitas metálicas e poliméricas para soluções em terra armada em solos não convencionais
Mots-clés en portugais
Ensaios de arrancamento
Interação solo-reforço
Resistência de interface
Terra armada
Resumé en portugais
Grande percentagem do território brasileiro é coberta por solos finos (% passando peneira # 200 > 50%), geralmente de origem tropical, que poderiam ser classificados como solos de baixa capacidade de drenagem. Estes solos não atendem às recomendações técnicas para solos de aterro de estruturas reforçadas, conforme exigido pela AASHTO e BS 8006. Neste trabalho foi avaliado experimentalmente um dos parâmetros mais importantes de projeto de Terra Armada, que condiciona o mecanismo de transferência de carga, o coeficiente de atrito aparente solo-fita metálica (f*). Foi avaliada a influência das características dos solos para as classes de solos estabelecidas pela NBR 9286/86 para o caso de fitas metálicas, e, dos critérios que sustentam o uso de fitas poliméricas, sob diversas tensões verticais atuantes nas fitas, simulando o efeito da profundidade. As informações foram obtidas através de ensaios de arrancamento de fitas metálicas e poliméricas realizados em laboratório e depois comparadas aos resultados teóricos da norma e àqueles preconizados para o uso de fitas poliméricas. Os ensaios realizados com as fitas em solo não convencional 1 e em areia mal graduada, mostraram que para profundidades equivalentes a tensões verticais até 50 kPa, os dois tipos de inclusões possuem valores de coeficiente de interação com o solo maiores que a unidade, isso tornaria razoável o seu uso sob o ponto de vista deste parâmetro e nas condições da realização dos ensaios, quando comparado com a norma, e com os critérios que sustentam o uso das fitas poliméricas em técnica de solo armado. No entanto, para maiores profundidades, a interação apresenta uma tendência de diminuição. O solo não convencional 2 valores da interação muito baixos. Foram instalados strain gages ao longo do comprimento das fitas para monitoramento dos esforços no maciço. Nota-se que esforços elevados ocorreram nas regiões mais próximas do ponto de aplicação da força de arrancamento.
Titre en anglais
Evaluation of the interaction of soil and metal strips and soil and polymeric strips applied to mechanically stabilized earth with concrete wall facing reinforce with unconventional soil
Mots-clés en anglais
Mechanically stabilized earth with concrete wall facing
Pullout tests
Soil-reinforcement interaction
Resumé en anglais
A large percentage of Brazil's territory is covered with fine tropical soil (50% passing #200) which can be classified as soils with low drainage capacity. These soils do not meet the technical recommendations for backfill of reinforced soil structures by AASHTO and BS 8006. This paper presents the result of an experimental evaluation of one of the most important design parameters of mechanically stabilized earth with concrete wall facing. The apparent friction coefficient of soil-steel strips and soil-polymeric strips is the project parameter. Also was evaluated the influence of soil characteristics for soil types listed by the NBR 9286/86 for metal strips and for the criteria that support the use of polymeric strips. The evaluation included the application of different vertical stresses on the strips simulating the effect of depth. The information obtained from pullout tests performed in laboratory was compared to the standard theoretical values and design values for polymeric strips. Tests performed on strips in nonconventional soil (1) and poorly graded sand showed that at depths equivalent to vertical stresses up to 50 kPa the two types of inclusions have coefficients of interaction greater than unity, which appears reasonable. Therefore, such soils can be used as backfill soils in the conditions tested and at equal or lesser stress levels. Nonconventional soil (2) showed low value of the friction coefficient. The strain gages installed along the length of the strips recorded the distribution of tensile stress in pull-out tests. Higher tensile stress was recorded by the gages nearest the point of application of the pull-out force.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2011-12-08
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.