Disertación de Maestría
DOI
https://doi.org/10.11606/D.18.2005.tde-07042006-113853
Documento
Autor
Nombre completo
Luciene Santos de Moraes
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2005
Director
Tribunal
Cintra, Jose Carlos Angelo (Presidente)
Aoki, Nelson
Beim, Jorge William
Título en portugués
Prova de carga dinâmica em placa
Palabras clave en portugués
prova de carga dinâmica
prova de carga direta
solo colapsível
Resumen en portugués
A prova de carga dinâmica é freqüentemente utilizada na determinação da capacidade de carga de fundações por estacas cravadas e há relatos de uso com sucesso deste ensaio em estacas escavadas e tubulões. Esta pesquisa envolveu a adaptação e execução da prova de carga dinâmica na placa de aço circular de diâmetro 0,80 m, com o objetivo de inferir a capacidade de carga do sistema placa-solo. Como a prova de carga dinâmica permite que seja feita a comprovação da carga durante a cravação, vislumbra-se também a viabilização desse tipo de ensaio em solos porosos por meio da cravação da placa o necessário para atingir a capacidade de carga exigida em um projeto. Os ensaios foram realizados no campo experimental da USP/São Carlos, com solo superficial não saturado, poroso e colapsível, por isso foram feitas medidas dos valores de sucção matricial, já que esta exerce forte influência sobre a capacidade de carga
Título en inglés
Dynamic load plate test
Palabras clave en inglés
colapsive soil
dynamic load test
plate load test
Resumen en inglés
The dynamic load test is frequently used in the determination of driven piles foundation bearing capacity. It is also reported the successful use of the test in bored piles and caissons. This research included the adaptation and execution of the dynamic load test in circular steel plate, to verify the bearing capacity of footing foundations. Since the dynamic load tests allow the bearing capacity to be verified during the construction, it is also glimpsed the possibility of using this test in porous soils by penetrating the plate into the soil until the expected bearing capacity is achieved. The tests were held at the USP/São Carlos experimental foundation camp, which has superficial unsaturated, porous and colapsive soil, so matric suction's measurement were made, since it has strong influence on the bearing capacity
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
dissertacao.pdf (5.87 Mbytes)
Fecha de Publicación
2006-04-13
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores