• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.17.2018.tde-23032018-123014
Documento
Autor
Nombre completo
Aline de Araújo Naves
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2017
Director
Tribunal
Muglia, Valdair Francisco (Presidente)
Júnior, Jorge Elias
Reis, Rodolfo Borges dos
Souza, Luís Ronan Marquez Ferreira de
Título en portugués
Valor adicional da sequência de difusão na acurácia diagnóstica da ressonância magnética no estadiamento linfonodal de pacientes com neoplasia de próstata
Palabras clave en portugués
Imagem de difusão por ressonância magnética
Imagem por ressonância magnética
Metástase linfática
Neoplasias da próstata
Resumen en portugués
INTRODUÇÃO: O adenocarcinoma de próstata (CaP) é a segunda neoplasia maligna de órgãos sólidos mais frequente em homens no mundo. As metástases linfonodais alteram o estadiamento e o prognóstico dos pacientes. O objetivo deste trabalho é avaliar a acurácia diagnóstica da Ressonância Magnética de próstata (RMP) na detecção de metástases linfonodais pélvicas e avaliar a acurácia dos critérios morfológicos, da imagem ponderada em difusão (DWI) e coeficiente de difusão aparente (ADC). MATERIAIS E MÉTODOS: No período de 1 de janeiro de 2015 a dezembro de 2016 foram avaliados, por dois observadores, 60 exames de RMP de pacientes que realizaram prostatectomia radical e linfadenectomia pélvica. Em momentos diferentes foi realizada análise morfológica (sequência ponderadas T2) e da DWI, com a medida do ADC e comparado o desempenho de ambas. RESULTADOS: Na análise por paciente da sequência T2 e DWI, a RMP apresentou uma sensibilidade variando de 45,5% a 63,6% e especificidade de 87,0% a 97,6%, sem diferença estatisticamente significativa. Já na análise por lesão os valores da sensibilidade variaram de 15,4% a 53,8% e a especificidade de 86,3% a 90,6%. Apenas para o observador 1 (menos experiente) a DWI aumentou a detecção de linfonodos. Não foi verificada diferença estatisticamente significativa entre as dimensões dos linfonodos positivos e negativos ou do ADC. CONCLUSÃO: A DWI não aumentou a acurácia diagnóstica da RMP no estadiamento linfonodal de pacientes com CaP. O critérios isolados de tamanho e o valor do ADC não apresentaram boa acurácia devido a sobreposição entre os valores dos linfonodos normais e patológico.
Título en inglés
Incremental value of diffusion-weighted imaging in diagnostic accuracy on lymph node staging of prostate cancer by Magnetic Resonance Imaging
Palabras clave en inglés
Diffusion
Lymphatic metastasis
Magnetic resonance imaging
Prostate cancer
Resumen en inglés
INTRODUCTION: Prostate cancer (PC) is the second most common malignancy in men worldwide. Lymph node metastases change the staging and prognosis of these patients. The objective of this study was to evaluate the adittional value of Diffusionweighted magnetic resonance imaging (DWI-MRI) using mean apparent diffusion coefficient (ADC) to lymph node staging of patients with PC. MATERIALS AND METHODS: Between January 2015 and December 2016, two observers evaluated 60 consecutive MRI exams of patients who underwent radical prostatectomy and pelvic lymphadenectomy. At different times, morphological analysis (T2 sequences) and DWI were performed with the ADC measurement and compared the performance of both. RESULTS: In per patient analysis of T2 and DWI images, MRI showed a sensitivity ranging from 45.5% to 63.6% and specificity from 87.0% to 97.6%, with no statistically significant difference. In per lesion analysis, sensitivity ranged from 15.4% to 53.8% and specificity from 86.3% to 90.6%. Only for observer 1 (less experienced) DWI increased lymph node detection. There was no statistically significant difference between dimensions of the positive and negative lymph nodes as well as ADC measurement. CONCLUSION: DWI did not increase the diagnostic accuracy of MRI in the lymph node staging of patients in PC. Mean ADC and lymph node size, alone or in combination, did not showed good accuracy due to the overlap between normal and pathological lymph node findings.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2018-07-20
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.