Master's Dissertation
DOI
https://doi.org/10.11606/D.17.2017.tde-30032017-090851
Document
Author
Full name
Edson Galdino do Nascimento Filho
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2016
Supervisor
Committee
Faça, Vitor Marcel (President)
Castro, Virgínia Picanço e
Moraes, Luiz Alberto Beraldo de
Title in Portuguese
Utilização do monitoramento de reações múltiplas para quantificação de produtos de interesse biotecnológico
Keywords in Portuguese
Espectrometria de massas
Fator VIII recombinante
Hemofilia A
Monitoramento de reações múltiplas
Abstract in Portuguese
A biotecnologia é definida como qualquer aplicação tecnológica que utilize sistemas biológicos, organismos vivos, ou seus derivados, para fabricar ou modificar produtos ou processos para alguma utilização específica (ORGANIZAÇÃO DAS NAÇÕES UNIDAS, 1992). Os produtos biotecnológicos devem atender certas especificações exigidas pela Agência Nacional de Vigilância Sanitária (ANVISA), Food and Drug Administration (FDA), European Medicine Agency (EMEA) e Wood Health Organization (WHO). Para isso, utilizam-se técnicas rotineiras aplicadas à pesquisa e análise de biomoléculas como Sodium Dodecyl Sulfate-Polyacrylamide Gel Electrophoresis (SDS-PAGE), Western blot, Enzyme-Linked Immunosorbent Assay (ELISA) e espectrometria de massas (MS). A abordagem do Monitoramento de Reações Múltiplas (MRM) é considerada uma interessante alternativa aos ensaios imunoenzimáticos para caracterização e quantificação total de proteínas terapêuticas, sejam elas recombinantes ou não (KIM e DOYLE, 2010). Esta abordagem é baseada nos fundamentos da proteômica quantitativa pela utilização da cromatografia líquida acoplada à espectrometria de massas sequencial (LCMS/MS) cuja plataforma apresenta alta especificidade, sensibilidade e reprodutibilidade quantitativa em suas análises para detecção simultânea de várias regiões da estrutura proteica. Em vista disso, estabeleceu-se uma metodologia para quantificação do FVIII recombinante (FVIIIr) produzido pela linhagem celular humana Sk-Hep-1 ou do FVIII derivado do plasma (FVIIIdp), ambos utilizados no tratamento da Hemofilia A (HEMA). Para o estabelecimento da metodologia, toda uma estratégia de seleção e síntese química de peptídeos representativos das cadeias pesada e leve do FVIII humano foi empregada. Tais peptídeos obtidos foram utilizados como padrões das análises. Além disso, foi demonstrada a relação direta entre a quantificação total do FVIII com técnicas convencionais como ELISA, possibilitando a aplicação rotineira dessa abordagem para quantificação do FVIIIr e do FVIIIdp.
Title in English
Utilization of multiple reaction monitoring for quantification of biotechnological interest products
Keywords in English
Hemophilia A
Mass spectrometry
Multiple reaction monitoring
Recombinant factor VIII
Abstract in English
Biotechnology is defined as any technological application that uses biological systems, living organisms, or derivatives thereof, to make or modify products or processes for a specific use (ORGANIZAÇÃO DAS NAÇÕES UNIDAS, 1992). Biotechnological products must meet certain specifications required by Agência Nacional de Vigilância Sanitária (ANVISA), Food and Drug Administration (FDA), European Medicine Agency (EMEA), and Wood Health Organization (WHO). For that routine techniques applied to research and analysis of biomolecules such Sodium Dodecyl Sulfate-Polyacrylamide Gel Electrophoresis (SDS-PAGE), Western blot, Enzyme-Linked Immunosorbent Assay (ELISA), and mass spectrometry (MS) are utilized as quality control techniques. The MS-based approach termed Multiple Reaction Monitoring (MRM) is considered an interesting alternative to immunoassays for the total quantification and characterization of therapeutic proteins, whether recombinant or not (KIM e DOYLE, 2010). This approach is based on the fundamentals of quantitative proteomics and uses of liquid chromatography coupled to tandem spectrometric mass (LC-MS/MS) to obtain a highly specific, sensitive and reproducible analysis for quantification of multiple regions of a given protein structure. Here, we established a methodology for total quantification of recombinant FVIII (rFVIII) produced in Sk-Hep-1 human cell line or of plasma derived FVIII (pdFVIII), both used in the treatment of Hemophilia A (HEMA). For that, we adopted a strategy of selection and chemical peptide synthesis of representative peptides of the heavy and light chains of human FVIII, which were used as standards in the analysis. The quantitative MRM method developed here indicated a direct correlation with FVIII quantitative techniques such ELISA, which allows routine application of such approach for rFVIII and pdFVIII quantification.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2017-04-24
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.