• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.17.2018.tde-13092018-152402
Document
Author
Full name
Lygia Bernardino Pereira
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2018
Supervisor
Committee
Haddad, Simone Kashima (President)
Martinez, Edson Zangiacomi
Prado Junior, Jose Clovis do
Slavov, Svetoslav Nanev
Title in Portuguese
Validação de kit imunocromatográfico rápido para detecção da doença de Chagas
Keywords in Portuguese
Doença de chagas ; Teste imunocromatográfico rápido ; Validação
Abstract in Portuguese
A doença de Chagas acomete entre 6 e 7 milhões de pessoas ao redor do mundo e acredita-se que a mesma seja responsável por 10.000 mortes/ano. A disponibilidade limitada de testes sorológicos sensíveis, específicos e rápidos para a doença dificulta o diagnóstico e o início precoce do tratamento em áreas endêmicas e não endêmicas. Neste estudo, realizou-se a validação de um teste imunocromatográfico rápido para detecção de anticorpos anti-T. cruzi da classe IgG (Imuno-Rápido Chagas, WAMA Diagnóstica). O desempenho do kit foi comparado ao de um kit comercial que utiliza a mesma metodologia (Comercial A) e às técnicas de ELISA e imunofluorescência indireta (IFI). Foram testadas 664 amostras de soro, as quais foram classificadas como reagentes e não reagentes considerando os resultados concordantes entre as metodologias de ELISA e IFI. O kit Imuno-Rápido Chagas apresentou sensibilidade de 98,5% e especificidade de 99,7%. Utilizando uma amostragem menor (n = 395), o desempenho desse teste rápido foi comparado ao do kit Comercial A. Nesta análise, o kit Imuno-Rápido Chagas apresentou uma sensibilidade de 98,1% e especificidade de 99,6%, ao passo que os valores de sensibilidade e especificidade encontrados para o kit Comercial A foram 98,7% e 99,6%, respectivamente. Por utilizarem antígenos recombinantes em suas composições e serem realizados em uma única etapa, os testes imunocromatográficos apresentaram sensibilidade inferior aos testes sorológicos convencionais. O kit Imuno-Rápido Chagas apresentou sensibilidade inferior ao kit Comercial A, o que pode ser explicado pelo volume menor de amostra utilizado no primeiro kit e pela reatividade do antígeno recombinante impregnado nos testes. Quando comparado com a literatura, nota-se que o kit Imuno-Rápido Chagas apresentou desempenho similar ou superior ao de outros testes rápidos disponíveis no mercado (SÁNCHEZ-CAMARGO et al., 2014). A sensibilidade analítica do teste avaliado foi de 0,235 UI/mL, e o kit mostrou ser mais específico frente a amostras reagentes para leishmaniose tegumentar do que a técnica de IFI. O teste manteve seu bom funcionamento oito meses após sua fabricação e após ter sofrido estresse de temperatura. Os resultados desse estudo sugerem que o kit Imuno-Rápido Chagas é capaz de detectar anticorpos da classe IgG anti-T. cruzi, apresentando valores de sensibilidade e especificidade comparáveis aos de outros testes comerciais. Sendo assim, o kit pode ser utilizado para auxiliar no diagnóstico da fase crônica da doença de Chagas.
Title in English
Validation of a rapid immunochromatographic kit for diagnosis of Chagas disease
Keywords in English
Chagas disease ; Rapid immunocromatographic test ; Validation
Abstract in English
Around 6 to 7 million people are infected by Chagas disease worldwide, and it is believed that this disease is responsible for 10,000 deaths/year. The lack of sensitive, specific and rapid serological tests for the disease hampers the diagnosis and the start of early treatment in endemic and non-endemic areas. This study validated a rapid immunocromatographic test for detection of IgG antibodies anti-T. cruzi (Imuno-Rápido Chagas, WAMA Diagnóstica). The kit's performance was compared to a commercial kit that uses the same methodology (Comercial A), to ELISA and to Indirect Immunofluorescence technique (IFI). A total of 664 serum specimens were tested, which were classified as reactive or non-reactive according to concordant results between ELISA and IFI. The sensitivity and specificity of Imuno-Rápido Chagas kit were 98.5% and 99.7%, respectively. The performance of this rapid test was compared to Comercial A using a smaller sampling (n = 395). At this analysis, the sensitivity and specificity of Imuno-Rápido Chagas kit were 98.1% and 99.6%, while the sensitivity and specificity of Comercial A kit were 98.7% and 99.6%, respectively. The immunochromatographic tests have shown lower sensitivity compared to conventional serological tests probably because they use recombinant antigens in their system and are performed in one-step. The Imuno-Rápido Chagas kit has shown lower sensitivity than Comercial A kit, which can be explained by the smaller amount of sample that is used in the first kit and by reactivity of the recombinant antigens used in the tests. Once compared to literature, Imuno-Rápido Chagas kit had the same or better performance than other commercial rapid tests available in the market (SÁNCHEZ-CAMARGO et al., 2014). The analytical sensitivity of the evaluated test in this study was 0.235 IU/mL, and the kit has shown a higher specificity than IFI regarding cutaneous leishmaniasis reactive samples. The test has maintained its good performance eight months after its manufacturing and after a temperature stress. The results of this study indicate that Imuno-Rápido Chagas kit is able to detect IgG antibodies anti-T. cruzi, showing sensitivity and specificity values comparable to other commercial tests. Therefore, the kit can be used to help on diagnosis of chronic phase of Chagas disease.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2018-10-04
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.