• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.17.2017.tde-07062017-150220
Documento
Autor
Nombre completo
Ester Serrano Ferreira
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2017
Director
Tribunal
Prata, Karen de Lima (Presidente)
Angulo, Ivan de Lucena
Souza, Helio Moraes de
Watanabe, Yeda Fumie
Título en portugués
Identificação dos fatores interferentes no transporte de concentrado de hemácias
Palabras clave en portugués
Concentrado de hemácias
Processos de validação
Temperatura externa
Temperatura interna
Transporte
Resumen en portugués
Introdução. O transporte é um procedimento crítico na manutenção da cadeia do frio do sangue. Falhas neste procedimento podem comprometer a sua qualidade e a segurança transfusional. Objetivo. Avaliar as não conformidades (NC) do Hemocentro de Ribeirão Preto relacionadas ao transporte de concentrado de hemácias (CH). Analisar caixas térmicas e gelos recicláveis submetidos à temperatura de 20°C e 30°C e propor melhorias neste processo. Métodologia. Estudo retrospectivo de NC relacionadas ao transporte de CH no software do sistema da qualidade do Hemocentro de Ribeirão Preto e pesquisa experimental realizada com três caixas diferentes em combinação com três gelos recicláveis distintos, simulando uma situação de transporte, nas temperaturas externas de 20°C e 30°C. Realizou-se uma estatística descritiva com os dados. Utilizou-se a metodologia de análise de variância (ANOVA), com o auxílio do software SAS® 9, utilizando a PROC GLM. Para as comparações foram utilizados contrastes ortogonais baseados na distribuição t. Resultados. Os resultados mostraram diferenças significativas no desempenho entre as caixas e entre os gelos recicláveis. No entanto, as maiores diferenças ocorreram entre as temperaturas externas de 20°C e 30°C, indicando a interferência da temperatura externa na temperatura do conteúdo interno. Outra diferença encontrada foi entre pontos de aferição das temperaturas, dentro da mesma caixa, indicando que a distribuição do ar, no interior da caixa não é homogênea. Conclusão. São vários os interferentes existentes durante o transporte de CH, que podem comprometer a qualidade do sangue. O transporte deve ser validado, padronizando o maior número de variáveis possíveis, para minimizar as adversidades que ocorrem durante o procedimento
Título en inglés
Identification of the interfering factors in packed red blood cells transportation
Palabras clave en inglés
External temperature
Internal temperature
Red blood cells
Transport
Validation process
Resumen en inglés
Introduction. The transport is a critical procedure in the maintenance of the blood cold chain. Failures in this procedure can compromise the blood quality and transfusion safety. Purpose: Evaluate the non-conformances (NC) of Hemocentro de Ribeirão Preto related to the Red Blood Cell (RBC) transport. Verify coolers, recycle ice at a temperature of 20°C and 30°C and propose improvements in this process. Methodology: Retrospective study of NC related to RBC transport in Hemocentro de Ribeirão Preto quality system software. Experimental research performed with three different insulated boxes combined with three different ice packs, simulating a situation of transport in the external temperatures of 20°C and 30°C. It was made a descriptive statistic of the data. The methodology of analysis of variance was used, through the software SAS® 9, using a PROC GLM. To do the comparisons orthogonal contrasts based on t distribution were used. Results: The results shown significant differences between insulated box and ice packs. However, the larger differences occurred between the temperatures of 20°C and 30°C, indicating that the external temperature interfere in the temperature inside the box. Another difference found was between points of temperature, inside the same insulated box, indicating that the air distribution inside the insulated box is not homogeneous. Conclusion. During RBC transport, many interfering exist that can compromise the blood quality. The transport must be validated, standardizing the largest number of details that is possible, to minimize adversity that occur during the procedure
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2017-08-10
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.