• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.17.2017.tde-29032017-161848
Document
Author
Full name
Isadora Orlando de Oliveira
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2016
Supervisor
Committee
Grossi, Debora Bevilaqua (President)
Marques, Amelia Pasqual
Costa, Leonardo Oliveira Pena
Fonseca, Marisa de Cássia Registro
Title in Portuguese
Valores de referência e confiabilidade de testes clínicos para avaliação funcional lombopélvica
Keywords in Portuguese
Coluna Vertebral
Dinamômetro de Força Muscular
Quadril
Resistência Física
Abstract in Portuguese
Introdução: Força, resistência e atividade muscular são uma área importante de pesquisa e avaliação contribuindo para um melhor entendimento de aspectos musculoesqueléticos de mecanismos de dor e lesão. No entanto, a utilização de testes que avaliem a região lombopélvica ainda é controversa, pois apesar de muitos testes clínicos estarem disponíveis na literatura, ainda não estão estabelecidos quais os mais confiáveis na prática clínica. Objetivos: Estabelecer valores de referência, determinar confiabilidade intra e interexaminador e as medidas de erro de um conjunto de testes clínicos que avaliam a região lombopélvica em indivíduos assintomáticos de diferentes gêneros, faixas etárias e níveis de atividade física. Materiais e Métodos: Para os valores de referência, 152 indivíduos (79 homens, 73 mulheres) estratificados por gênero, faixa etária e nível de atividade física realizaram um conjunto de nove testes clínicos: força isométrica máxima de abdutores, extensores, flexores e rotadores laterais de quadril, resistência nas posições de ponte lateral, ponte frontal, flexores e extensores lombares e atividade muscular da região lombopélvica. Para a confiabilidade, 33 indivíduos foram avaliados por dois examinadores em um intervalo de 3 a 7 dias, onde realizaram aleatoriamente o mesmo conjunto de testes. As medidas de confiabilidade foram avaliadas pelo Coeficiente de Correlação Interclasse (CCI2,1) e as medidas de erro definidas pelo Erro Padrão da Medida (EPM) e pela Mínima Mudança Detectável (MMD). Resultados: Foram observadas diferenças significativas (p<0.05) nos testes clínicos para as variáveis: gênero, faixa etária e nível de atividade física e estabelecidos valores de referência para cada grupo. Todos os testes apresentaram valores de confiabilidade excelente com CCI (IC 95%) maior que 0.8 para as confiabilidades intra e interexaminador; os valores da MMD foram superiores à média do EPM em todos os testes. Conclusão: Os resultados do presente estudo apontam valores de referência que contribuem com o estabelecimento de referências para auxiliar na tomada de decisões clínicas. Além disso, este conjunto de 10 testes apresentou confiabilidade intra e interexaminador bem como valores de EPM e MMD, confirmando a possibilidade de seu uso na prática clínica.
Title in English
Reference values and reliability for tests of lumbopelvic functional assessment
Keywords in English
Hip
Muscle Strength Dynamometer
Physical Endurance
Spine
Abstract in English
Background: The assessment of the lumbopelvic region is useful for many musculoskeletal dysfunctions. Several clinical tests are commonly used to assess this region, however, reference values for clinical assessments and results concerning method, reliability and error measurements of these tests have not been reported. Objectives: To establish reference values and to determine intra and interrater reliability, standard error of measurement (SEM) and minimum detectable change (MDC) of a set of clinical tests used for assessing the lumbopelvic region in asymptomatic volunteers of different gender, age groups and physical activity levels. Methods: For reference values, 152 subjects (79 men, 73 women) divided by gender, age group and physical activity levels, performed nine clinical tests: Maximum voluntary isometric strength of hip abductors, extensors, flexors and lateral rotators, transversus abdominis(TrA) muscle activity (using a Pressure Biofeedback Unit), prone and side bridges, trunk flexor and extensor endurance tests. To measure reliability, 33 individuals performed the same set of tests, in random order within a week period. Intrarater and interrater analysis were assessed using the Intraclass Correlation Coefficient (ICC) and the error measurements were defined by using the SEM and the MDC. Results: Reference values were established for each group and our results showed significant (p<0.05) differences concerning gender, age group and physical activity levels in clinical tests. In general, strength differences were related to gender and physical activity levels and endurance results could be related to interactions between gender, age group and physical activity levels. All tests presented good reliability indices with an ICC (95%CI) higher than 0.8 for the intrarater and interrater reliability; MDC values were greater than mean of SEM in all tests, confirming its usage for clinical practice assessments. Conclusion: Reference values are necessary to help clinicians in the evaluation of subjects and these results can contribute for clinical practice in providing clinical training targets. Also, this set of tests presented good intra and interrater reliability measures of strength, endurance and TrA muscle activity test as well as SEM and MDC values, confirming its use for assessing the lumbopelvic region.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2017-04-24
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.