Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.17.2014.tde-07062015-155700
Documento
Autor
Nome completo
Alessandra Fabiane Lago
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
Ribeirão Preto, 2014
Orientador
Banca examinadora
Barbas, Carmen Silvia Valente
Título em português
Avaliação do consumo de oxigênio e do gasto energético durante o teste de respiração espontânea
Palavras-chave em português
Calorimetria indireta
Desmame do respirador
Insuficiência respiratória
Unidade de terapia intensiva
Ventilação mecânica
Resumo em português
Introdução: O desmame ventilatório é definido como o processo de liberação do suporte ventilatório e como avaliação dessa fase é conduzido o Teste de Respiração Espontânea (TRE). Um dos mais utilizados modos de TRE é a Pressão Positiva Contínua em Vias Aéreas (CPAP), a qual se aplica uma pressão positiva contínua tanto na inspiração quanto na expiração. Contudo, junto com os modos ventilatórios pode ser utilizado a Compensação Automática do Tubo (ATC) cujo objetivo é compensar a resistência imposta pelo tubo endotraqueal. Objetivos: O principal objetivo deste estudo foi comparar o Consumo de Oxigênio (VO2) a o Gasto Energético (GE) pela calorimetria indireta (CI) durante o TRE em CPAP com e sem a ATC. Métodos: O estudo foi randomizado, controlado tipo cross-over com quarenta pacientes em nove leitos de um Centro de Terapia Intensiva de um hospital terciário universitário (Hospital das Clínicas de Ribeirão Preto Universidade de São Paulo, Brasil). Os participantes foram alocados aleatoriamente no grupo 1, no qual era iniciado o TRE em CPAP em uso da ATC e posteriormente em CPAP sem o uso da ATC, ou no grupo 2, no qual era iniciado o TRE em CPAP sem a ATC e em seguida CPAP com a utilização da ATC. Resultados: Cinco pacientes foram excluídos depois da randomização por falha durante o TRE. Dos trinta e cinco restantes a maioria foi do sexo masculino (51%). A média de idade foi de 61,4 ± 16,1 anos. A diferença de VO2 entre os TREs com ATC e sem ATC foi de -1,6 mL.Kg-1.min-1; p=0,23 e intervalo de confiança de 95%: (-4,36; 1,07). Em relação ao GE a diferença foi de -5,4 kcal/d-1; p=0,5 e intervalo de confiança de 95%: (-21,67; 10,79) durante a comparação dos TREs em CPAP com e sem ATC. Conclusão: Não foram observadas diferenças quando se comparou os valores relacionados ao VO2 e GE durante o TRE com e sem ATC.
Título em inglês
Evaluation of oxygen consumption and resting energy expenditure during spontaneous breathing test
Palavras-chave em inglês
Indirect calorimetry
Intensive care unit
Mechanical ventilation
Respiratory insufficiency
Ventilator weaning
Resumo em inglês
Introduction: Weaning from mechanical ventilation is defined as the process of release of ventilatory support and how the evaluation of this phase is conducted in the spontaneous breathing test (SBT). One of the most used modes of SBT is the Continuous Positive Airway Pressure (CPAP)which applies a continuous positive pressure in both inspiration and expiration. However, together with the mechanical ventilation modes it can be used the Automatic Tube Compensation (ATC) which compensates the resistance imposed by the endotracheal tube. Objectives: The main goal of this study was to compare the Oxygen Consumption (VO2) and Resting Energy Expenditure (REE) by indirect calorimetry (IC) during the SBT in CPAP with and without ATC. Methods: The study was a prospective randomized, controlled crossover trial, that enrolled 40 patients, in a 9-bed Intensive Care Unit of a tertiary University Hospital. (Clinics Hospital of Ribeirão Preto Medical School, University of São Paulo, Brazil). Participants were randomly allocated in Group 1, in which it was started the SBT in CPAP with ATC and later on CPAP without ATC, or in Group 2, which was started the SBT on CPAP without ATC and then CPAP with ATC.Results: Five patients were excluded after randomization for failure of the SBT. The thirty-five remaining patients were most male (51%). The mean age of the sample was 61.4 ± 16.1 years. The difference of VO2 between the SBT with ATC and no ATC obtained a value of -1.6 mL.Kg-1.min-1; p = 0.23 and 95% confidence interval: (-4.36; 1.07). To analyze the difference of REE between the SBT with ATC and no ATC, it was obtained an estimated value of -5.4 kcal/d-1, p = 0.5 and 95% and confidence interval (-21.67; 10.79). Conclusions: There were no differences in the comparison of VO2 and REE during the SBT with and without ATC.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
d.pdf (2.50 Mbytes)
Data de Publicação
2015-08-14
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.