• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.17.2019.tde-22052019-111721
Document
Author
Full name
Rodrigo Otávio do Espírito Santo
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2018
Supervisor
Committee
Cruz, Antonio Augusto Velasco e (President)
Alencar, Victor Marques de
Garcia, Denny Marcos
Gonçalves, Allan Christian Pieroni
Messias, André Márcio Vieira
Title in Portuguese
Retração da pálpebra inferior na orbitopatia de Graves: uma análise quantitativa do contorno palpebral
Keywords in Portuguese
Contorno palpebral
Curva de Bézier
Orbitopatia de Graves
Pálpebra inferior
Retração palpebral
Abstract in Portuguese
Objetivos: descrever um novo método, baseado nas curvas de Bézier, de obtenção e análise quantitativa do contorno da pálpebra inferior de pacientes com orbitopatia de Graves. Casuística e Métodos: Foram estudados dois grupos de sujeitos, pareados por sexo e idade, sendo 41 pacientes portadores de orbitopatia de Graves e 43 sujeitos normais. Foi realizada exoftalmometria de Hertel em todos os integrantes do estudo e empregados cortes coronais de ressonância magnética orbitária para medir a área do músculo reto inferior de 17 pacientes e 16 controles. O programa ImageJ, com a ferramenta da curva de Bézier, foi usado para obtenção do contorno palpebral inferior de um dos olhos de todos os integrantes dos dois grupos da partir de fotografias digitais da fenda palpebral. O programa MatLab foi utilizado para se obterem, de ambos os grupos, o pico do contorno palpebral inferior, a distância margem reflexo 2 (MRD2), o índice de circularidade do contorno da pálpebra, o ângulo lacrimal, a área de exposição escleral delimitada pelo contorno palpebral bem como a razão entre as áreas temporal e medial dessa área. Resultados: A análise do contorno da porção ciliar da pálpebra inferior demonstrou que a retração palpebral está significativamente correlacionada ao grau de proptose do olho nos pacientes portadores de orbitopatia de Graves e ao deslocamento inferior do tubérculo lacrimal. Não houve correlação entre a magnitude da retração e o aumento da área do músculo reto inferior. O contorno da porção ciliar da palpebral inferior não apresentou deformações setoriais, achado este comprovado pela ausência de diferença significativa da posição do pico palpebral entre os dois grupos estudados, pela distribuição simétrica entre as áreas temporal e medial do contorno palpebral e pelo maior grau de circularidade detectado nas pálpebras dos portadores de orbitopatia de Graves. A retração deslocou significativamente o tubérculo lacrimal da pálpebra afetada. Conclusão: A curva de Bézier mostrou-se uma ferramenta útil para o estudo do contorno palpebral inferior. A análise do contorno evidenciou que não há flare temporal na retração palpebral inferior na orbitopatia de Graves. Os resultados possibilitaram melhor entendimento da retração palpebral, assim como planejamento cirúrgico mais preciso para correção dessa patologia palpebral.
Title in English
Graves lower eyelid retraction: a qualitative eyelid contour analysis
Keywords in English
Bézier curves
Eyelid contour
Eyelid retraction
Graves orbitopathy
Lower eyelid
Abstract in English
Purpose: To describe a new method, based on the Bézier curves, to obtain and analyze quantitively the lower eyelid contour of patients with Graves orbitopathy. Magnetic. Casuistic and Methods: Two groups of sex and age matched subjects were studied: patients with Graves orbitopathy (n = 41) and normal controls (n= 43). Hertel exophthalmometry was performed in all subjects. Coronal slices of Magnetic resonance imaging were employed to estimate the area of the inferior rectus muscle of 17 patients and 16 controls. The Image J NIH software, equipped with the Bézier plugin, was used to obtain the lower eyelid contour of one eye of all participants from digital images of the palpebral fissure. With the software Matlab it was measured in all contours the following variables: margin reflex distance 2, the contour peak, the circularity index, the lacrimal angle and the total area of the lid contour as well the medial and lateral portions of this area. Results: The contour analysis of the ciliated portion of the lower eyelid showed that the lid retraction is significantly correlated with the degree of proptosis and with the displacement of the lacrimal tubercle of the lid. There is no correlation between the magnitude of retraction and the inferior rectus area. The ciliated portion of the lower eyelid does not show segmental deformities as demonstrated by the absence of difference between the temporal and medial areas of the contour as well by the highest index of circularity of the retracted lids. Lower eyelid retraction displaces significantly the lacrimal tubercle of the affected lid. Conclusions: The Bézier curve proved to be a useful tool for the study of the lower eyelid contour. The contour analyis showed that there is no lateral flare on the lower eyelid retraction of the Graves orbitopathy. The results allow a better understanding of the lid retraction and a precise surgical planning of this lid pathology.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2019-08-16
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.