• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.17.2018.tde-17042018-141102
Documento
Autor
Nombre completo
Giseli Rebechi
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2018
Director
Tribunal
Tamashiro, Edwin (Presidente)
Martins, Regina Helena Garcia
Ricz, Hilton Marcos Alves
Valera, Fabiana Cardoso Pereira
Título en portugués
Avaliação da histocompatibilidade do implante de ácido glicólico/ácido lático (PLGA) na laringe de coelhos
Palabras clave en portugués
Colágeno; Histologia; Implante; Laringe
Resumen en portugués
Introdução: Diversas afecções laríngeas exigem o uso de enxertos para correção de insuficiências anatômicas ou de múltipla aplicação de fármacos para controle da doença. Alguns bioimplantes, especialmente aqueles com propriedades de liberação controlada de drogas, podem ser úteis no tratamento dessas afecções laríngeas, como a papilomatose laríngea. O poli ácido lático-co-glicólico (PLGA), tem sido bastante testado em aplicações intraoculares e topicamente na cavidade nasal, com resultados bastante promissores. No entanto, um implante de PLGA nunca foi avaliado quanto à sua biocompatibilidade em tecidos laríngeos. Objetivo: Avaliar as alterações histológicas decorrentes da aplicação de PLGA em laringes de coelhos. Materiais e Métodos: Grupos de sete a oito coelhos foram sacrificados em diferentes tempos pós-manipulação cirúrgica (1, 2, 4 e 8 semanas), comparando o lado implantado com PLGA e o lado sham-operado. Os achados histopatológicos foram comparados entre os dois grupos em cada tempo cirúrgico, assim como foi avaliada a diferença comparada a laringes não manipuladas. Resultados: A implantação de PLGA promoveu maior infiltração de células inflamatórias, indução de fibrose e neovascularização até a 4ª semana pós-operatória avaliada. No entanto, após oito semanas de evolução, as hemilaringes implantadas com PLGA se apresentaram semelhantes às laringes sham-operadas, ou mesmo não manipuladas cirurgicamente, com retorno quase que completo às condições basais. Por outro lado, não houve diferença da quantidade de depósito de colágeno tipo I e III nas hemilaringes implantadas com PLGA, em nenhum dos tempos avaliados. Conclusão: O implante de PLGA parece ser seguro para aplicações intralaríngeas, produzindo reações inflamatórias nas quatro primeiras semanas, mas que são reversíveis em oito semanas.
Título en inglés
Evaluation of histocompatibility of poly lactic-glycolic acid graft in rabbit larinx
Palabras clave en inglés
Collagen; Histology; Implant; Larynx
Resumen en inglés
Introduction: Several laryngeal affections require the use of grafts to correct anatomical insufficiencies or multiple application of drugs to control the disease. Some bioimplants, especially those with controlled drug release properties, may be useful in the treatment of such laryngeal conditions, such as laryngeal papillomatosis. Poly (lactic acid-co-glycolic acid), PLGA, has been widely tested in intraocular and nasal cavity applications, with very promising results. However, a PLGA implant has never been assessed for its biocompatibility in laryngeal tissues. Aim: To evaluate the histological changes resulting from the application of PLGA in rabbit larynx. Materials and Methods: Groups of 7-8 rabbits were sacrificed at different postsurgical times (1, 2, 4, and 8 weeks), comparing the implanted side with PLGA and the sham-operated side. Histopathological findings were compared between the two groups at each surgical time, as was the difference compared to the non-surgically manipulated larynx. Results: PLGA implantation promoted a higher infiltration of inflammatory cells, induction of fibrosis and neovascularization until the 4th postoperative week evaluated. However, after 8 weeks of evolution, PLGA implanted hemilarynx were similar to sham-operated or even non-surgically manipulated larynx, with a complete return to baseline conditions. On the other hand, there was no difference in the amount of collagen deposition type I and III in the hemilarynx implanted with PLGA, in none of the evaluated times. Conclusion: The PLGA implant appears to be safe for intralaryngeal applications, producing inflammatory reactions in the first 4 weeks, but which are reversible within 8 weeks.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
GISELIREBECHI.pdf (1.57 Mbytes)
Fecha de Publicación
2018-06-13
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.